Herunterladen Inhalt Inhalt Diese Seite drucken

General Installation Guidelines - Tecsis F5308 Serie Originalbetriebsanleitung

Kraftaufnehme
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.2

General installation guidelines

• The loads operating upon the load pin must be introduced perpendic-
• Torsion and shear forces need to be avoided. Components of angular
ular in the load direction.
applied measured variables are also a part of transverse loads and
• Torsional moments, transverse or centric loads and side forces cause
lateral forces.
• The axle bracket grooves also serve as a reference for aligning and
measurement errors and can damage the load pin permanently.
• The DIN 15058 axle bracket must be attached in such a way that the
fix the load pin against rotation.
measuring axle is prevented from twisting in the bearing and does not
have any axial play. The axle bracket and the attaching must not be
loaded by example the axle load. The Axle bracket must be
• The measuring axle may only be subjected to load if the correct type
secured with undetachable fixing.
of bearing has been used. Loads occurring in other equipment may
• The introduction of force in the centre must not wander and must be
change the zero signal and result in permanent damage.
installed in such a way that axial shifts are prevented. However, force
by-passing may not occur.
www.tecsis.de
Fig. 5 Installation situation of a load pin
Betriebsanleitung/Operating manual
Earth
connection
(M6 8/12
deep)
BD_BE 991 d
F5308/F53C8/F53S8
Axle bracket acc. to DIN
symbol lasered
„force direction"