Herunterladen Inhalt Inhalt Diese Seite drucken

Tecsis F5308 Serie Originalbetriebsanleitung Seite 42

Kraftaufnehme
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Betriebsanleitung/Operating manual
F5308/F53C8/F53S8
Model series
Measurement range
Rated force
Accuracy and stability
2)
Relative linearity error
3)
Repeatability
Temperature effect on zero signal
Temperature effect on characteristic value
Mechanical characteristics
Force limit
Breaking force
4)
Lateral force effect
Rated displacement
Material of measuring spring
Temperature ranges
Rated temperature range
Operating temperature range
Storage temperature range
Electrical characteristics
Current consumption
Supply voltage
Burden
Response time
General data
Protection (acc. to EN 60529/IEC 529)
Vibration resistance
(acc. to DIN EN 60068-2-6)
Electrical protection
Emission
Immunity
Electrical connection
Options
1)
The load pins with ignition protection type "ib" must only be supplied using galvanically-isolated power supplies.
Suitable supply isolators are also optionally available eg. EZE08X030003
2)
Relative linearity error is specified acc. to VDI/VDE/DKD 2638 chapter 3.3.6 b.
3)
Acc. to VDI/VDE/DKD 2638 Relative repeatability error in unchanged mounting position.
4)
This value can be reached when 100% F
5)
Other SIL-shifts are available on request.
6)
Other response times are available on request.
42
Symbol
Unit
F
kN
nom
d
%
lin
b
%
rg
TK
%/10 K
0
TK
%/10 K
C
F
x%F
L
nom
F
x%F
B
nom
d
x%F
Q
nom
s
mm
nom
B
°C
T, nom
B
°C
T, G
B
°C
T, S
mA
V
mA
VDC
Ohm
ms
act. 90° rotated to the axis.
nom
F53C8 version
1)
ATEX/IECEx Ex ib
corrosion resistant stainless steel
ultrasonic tested 3.1 material / (optionally 3.2)
operating temperature range see chapter
10.1 and 11.1 on a page 45-47
(4...)20, 2-wire
-
4 ... 20 mA 2-wire: si-
Current output
4 ... 20 mA 2-wire:
signal current
10...30 for current output
≤ (UB–10 V)/0,024 A for current output
> 10 kΩ voltage output
≤ 2 (within 10% bis 90% F
20 g, 100 h, 50...150 Hz
Reverse voltage, overvoltage and short-circuit protection
acc. DIN EN 61326-1/DIN EN 61326-2-3
(optional EMC ruggedized version)
Circular connector M
12x1, 4-pin,
MIL connector,
Cable gland
Certificates, Strength tests,
3D-CAD data (STEP, IGES) on request
BD_BE 991 d
F53C8 version
F53C8 version
ATEX/IECEx EX d
EN 62061:2005
10 and higher
± 1 / ± 1.5
0.2
0.2
0.2
200
500
± 5
< 0.1
-20...80
-40...85
(4...)20, 2-wire
4 ... 16, 2-wire
(4...)20, 3-wire
2 ... 8, 3-wire
Current output
Current output
4 ... 20 mA 2-wire:
gnal current,
Current output
Current output
4 ... 20 mA 3-wire:
4 ... 20 mA 3-wire:
<8 mA
Voltage output:
voltage output
6)
)
nom
IP67
DIN EN 55011
Cable gland
Circular connector
(only cables which
M 12x1, 4-pin,
approved for
ATEX/IECEx Ex d)
www.tecsis.de
SIL-3 acc.
-30...80
5)
5)
signal current,
<8 mA
< 8 mA
10...30 for
current output
14 ... 30 for
Cable gland

Werbung

Inhaltsverzeichnis
loading