ATEX version Ex ib

10

10.1 Information

This insert supplements and supersedes the information in the pre-
vious operating instructions BD914_d. It applies to explosion-proof
equipment with the following classification: EN 60079-0:2012/
EN 60079-11:2012 (Ex ib).
II 2G Ex ib IIC T4 Gb
II 2G Ex ib IIC T3 Gb
I M2 Ex ib I Mb
II 2G Ex ib IIC T4 Gb
Certification office 0158
Prototype certification IECEx BVS08.0028X / BVS 08 ATEX E 075 X
The normal installation instructions in the operating instructions ap-
ply. No special settings are required.
Special conditions for safe use
Ambient temperature ranges of the load pins
Type
F*3C*.****.12*************
F*3C*.****.14*************
F*3C*.****.15*************
F*3C*.****.16*************
F*3C*.****.17*************
F*3C*.****.21*************
The permanently connected cable of load pins type
F*3C*.****.15************* and type F*3C*.****.21************* have
to be mechanical fixed in installation.
www.tecsis.de
-25°C < Tamb < +85°C
-25°C < Tamb < +100°C
-25°C < Tamb < +85°C
-40°C < Tamb < +85°
(for cabel connection only)
Temp.
Ambient temperature
class
range
T4
-25°C up to +85°C
T3
-25°C up to +100°C
Group I
-25°C up to +85°C
T4
-40°C up to +85°C
T4
-40°C up to +85°C
T3
-40°C up to +100°C
T4
-45°C up to +85°C
T3
-45°C up to +100°C
T4 and
-40°C up to +85°C
Group I
BD_BE 991 d