CC‐Link and Ethernet Gateway for AED/Fit components
Tip
There are repeated references below to the relevant AED/FIT station
commands (3‐letter abbreviation after a command or parameter, frequently in
brackets). Detailed information about the individual commands can be found
in the AED/FIT component online Help.
10.1 Parameter transmission, PLC -> gateway
Assignment of the RY bit area
Bit
Content and description
0 3
Selector:
0000 = Idle
0011 = Parameter container (SDO)
4
0
5
0
6
0
7
Toggle In
8 11
SDO command:
0000 = Idle
0001 = Read SDO
0010 = Write SDO
12 15
not evaluated
Bits 0 3 specify the type of container requested:
0x00:
Idle, no request
0x03:
Parameter container for SDO
Bit 7 (Toggle In): Toggle bit, the gateway inverts the bit and sends it back.
Bits 8 11 specify the type of container requested:
0x00:
Idle, no acyclic operation
0x01:
acyclic access to the AED/FIT station (read parameters)
0x02:
acyclic access to the AED/FIT station (write parameters)
Assignment of the RWw word area
Bit
Content and description
0 7
Selection of CAN address of AED/FIT 1 128
8 15
0
16 31
Attribute index (see Section 10.5, page 34)
32 47
Write parameter value, bits 0
48 64
Write parameter value, bits 16
A3330-1.0 en/de
15
31
29
HBM