Communication via Modbus/TCP

The gateway gives you direct access to the AED/FIT stations on the CAN Bus
via Modbus/TCP. You can access both the cyclic (PDO) and acyclic data
(SDO) of the AED/FIT stations, and you can configure the gateway via
Modbus/TCP.
Gateway communication protocols
DHCP
HBM
IPscan&config
UDP
Important
It is only possible to configure the CC‐Link interface via the web interface or
the Modbus/TCP interface.
It is necessary to restart the gateway to activate all the changes.
A fixed memory area of 10 bytes, over which measured values are
transmitted, is allocated for the cyclic data of each station address, for
communication with the connected AED/FIT stations.
The Modbus function "Encapsulated Interface Transport" is used for acyclic
access to all the parameters of the connected stations.
The tables in this section make use of the following abbreviations:
Abbreviation
Meaning
UINT8
8‐bit unsigned integer
UINT16
16‐bit unsigned integer
UINT32
32‐bit unsigned integer
Attribute
Access attribute; possible values:
HBM
CC‐Link and Ethernet Gateway for AED/Fit components
Function 0x03: Read holding register
Function 0x10: Write multiple register
Function 0x2B: CiA309-2 (Encapsulated
Interface Transport)
RO = Read Only
RW= Read/Write
WO= Write Only
Modbus
TCP
IP
HTTP web
interface
A3330-1.0 en/de