Herunterladen Inhalt Inhalt Diese Seite drucken

Honeywell IDENTLOC slimline Montage, Anschluss, Anleitung Seite 12

Verschluss-sensor
Vorschau ausblenden Andere Handbücher für IDENTLOC slimline:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

12
4.5
Mounting the locking sensor
Attention!
When mounting the sensor, observe that a "positive signal" may only be given if at
least half (50%) of the locking bolt of the locking system is inserted in the anchorage
of the fittings.
We recommend installing the
corresponding mounting and connection instructions for information about the
installation of the transmission unit.
The following section describes the installation in window fittings. The same
procedure applies to the installation in a door.
Selecting the mounting position
-
Open the window. Move the locking bolt to the position to be monitored (normally "closed")
while the window is open.
-
Select a locking bolt of the multiple lock.
-
Check the following carefully:
-
It must be possible to hang on and mount the adapter plate via this bolt.
Note:
The play between the bolt and the adapter plate is reduced to a minimum by means
of the fixing plate during the final mounting.
-
Install the transmission unit in the frame in such a way that the transmission markings of
the sensor and transmission unit are opposite each other in the monitored state.
-
Make sure that the required distances and max.
admissible mounting tolerances are complied with
when installing the sensor and transmission unit:
The
clear distance "a"
should be
2 mm to 5 mm
The maximum admissible distance (10 mm)
should not be used if possible.
If the distance is too large, it is possible to mount
the transmission unit at a distance. In this case,
use the
surface mounted base
(see chapter 8 "Accessories").
If the available distance is too small, it is possible to
embed
the transmission unit in case of wooden or
plastic constructions (see manual of the transmissi-
on unit).
The
lateral offset
must not exceed
- Ensure that the locking function is not impeded by the installation of the sensor (sliding
space of the locking pieces):
Move the bolt into the opened position or with turn and tilt fittings into the middle position.
The installation site for the guide plate is approximately in the middle of the adapter plate.
Hold the guide plate at this point and check whether the bolt can move into all positions
without being impeded.
Note:
If the retaining plate has a deepended armature profile, the recess underneath the
guide plate must be compensated for by an plain washer or equivalent. If the fixing screw is
then too short, the recess in the guide plate must be made deeper.
The
ínstallation site
Mounting and Connection Instructions
between the housings
.
Item no. 030110
of the housings in all directions
2 mm
.
is only
suitable
when
IDENTLOC
sensor first
and then the transmission unit. See the
window leaf
locking
sensor
2 mm max.
transmission distance 2 mm to 5 mm
(falling below 2 mm is not allowed)
all
requirements have been fulfilled!
Locking Sensor
slimline
adapter plate
window frame
transmission
unit
transmission
marking
a

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

032236.17

Inhaltsverzeichnis