Commissioning
Description of settings
Combustion air
SQM 10 16
10
Downloaded from
www.Manualslib.com
Servomotor Y10
1
Connection terminal board
2
Cam setting key
3
Seven adjustable graduated cams
4
Lever to operate the motor release
mechanism
5
Non adjustable graduated cylinder
for servomotor position
6
Graduated cylinder indicator
Cam functions
CamFunction
I
Nominal air flow
II
Air closure on shutdown 0
III
Firing air flow
IV
Free 0°
V
Cam V provides the minimum
control flow information (to be set
between the values of cam I and
VI)
VI
Minimum control air flow
VII
Simultaneously powering up of the
large flame indicator and lower
hour meter at nominal flow rate
only
• Set this a few degrees lower than
the value read on cam I.
T yp e
E S 0 8 .
5 2 0 0
05/2009 - Art. Nr. 4200 1017 4400A
manuals search engine
Cam VI determines the automatic minimum
control flow after the ignition phase. In the
electric control cabinet, the timer K6 sets
itself at ≅15s.
Setting
• Remove the cover.
• Check the cam drum reset.
• Pre-set the cams according to the boiler
In order to do this:
• Adjust the cams manually or with the
B u r n e r
A ir s e ttin g in °
p o w e r
i g n itio n
k W
c a m III
7 0 0
2 5
3 1 0 0
-
5 2 0 0
-
capacity and to the values read on the
table enclosed.
key. The angular position can be read
from the indicators located on each
cam.
F r e q u e n c y in H z
n o m in a l
Ig n itio n
N o m in a l
c a m I
-
3 0
7 0
-
5 1
8 0
-
5 7
-