8 Ensure that the Mirror Pair field for the remaining drive is set to Secondary.
9 Press <Esc> to exit the Adapter Properties Menu.
10 Select Save changes and exit this menu and press <Enter>.
11 Press <Esc> to exit the Main Menu.
12 Select Exit the Configuration Utility and press <Enter>.

Additional Integrated Mirroring Guidelines

10
General System Configuration
Downloaded from
www.Manualslib.com
The drive that is set to secondary will mirror the primary drive. All other data on the
secondary drive will be lost.
After pressing <Enter>, you are prompted to confirm the change by pressing <Enter> again
and then by pressing <F3>.
The server module reboots and shows mirrored status after POST.
The hard-drive status indicator does not display any status information until after the
operating system driver initialization has occurred. To check for status information of a hard
drive prior to operating system load, use <Ctrl><M> during POST. See the Dell PowerEdge
Expandable RAID Controller 4/IM User's Guide for more information. During normal
operation, the status indicator is off.
NOTE:
The hard-drive activity indicator functions normally before and after the operating system
driver initialization.
NOTICE:
If you use a drive with existing data, the data will be cleared before the hard drive is added to
a mirror.
It is recommended that any replacement drives should be blank and not previously
configured.
It is recommended that you replace hard drives in an integrated-mirror configuration with
drives of the same capacity.
After removing a hard drive in a hot-pluggable environment, wait at least 30 seconds prior
to installing the new hard drive.