Outer dimensions and technical data

42
Nominal thermal output (NWL)
Partial-load thermal output
Space heating capacity
Degree of efficiency
CO content at NWL
CO content at partial-load
Flue gas temperature at NWL
Flue gas mass flow rate at NWL
Flue gas mass flow rate at partial-load
Holding capacity, full tank
Fuel
Pellet consumption min./max
Autonomy min./max
Air connector Ø
Flue connector Ø
Current upon switching on
Operating current
Voltage / current frequency
Voltage fluctuations
Frequency fluctuations
Dimensions
H x W x T
Weight
Minimum spacing
Temperature limits
Relative humidity
Installation location
above sea level
8 kW
2.4 kW
55 – 190 m³
> 90%
<180 mg/Nm³
155 mg/Nm³
150 ° C
4.4 g/s
3.2 g/s
26 kg / 40 l
Pellets
0.6 – 1.8 kg/h
approx. 12 - 40 h
80 mm
100 mm
300 W
50 W
230 V / 50 Hz
0.9 - 1.1 of the rated voltage
0.99 - 1.01 of the rated frequency, constant
0.98 - 1.02 short-term
1100 x 526 x 498 mm
150 kg
side
150 mm
rear
100 mm
front
800 mm
0 - 40°C
non-condensing
< 1000 m