Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

english

1. TECHNICAL DATA

As a stove of construction type 1, it is possible to connect it to the chimney together with an exisiting other stove or
another hearth for solid fuels, as long as the chimney dimensioning complies with DIN 4705, Part 3.
TECHNICAL DATA
Height
Width
Depth
Weight
Flue pipe outlet diameter
Nominal thermal output (EN 13240)
Maximum thermal capacity
Smallest heating capacity
Room heating capacity
(depending on building insulation)
Exhaust values for multiple use of the chimney in accordance with DIN 4705, Part 3 and for the calculation
of the chimney measurements in accordance with DIN 4705, Part 2
Flue gas mass flow closed
Flue gas temperature closed
Minimum feed pressure closed
Nominal thermal output
Minimum feed pressure
Nominal thermal output
at 0.8 times n. ther. outp.
Required safety distances (Minimum distances) - towards flammable materials
a – toward the front in the radiated area
b – to the side
c – to the back
d – to the ceiling
e – to the side glass
*1: A wall installation with a 0 mm distance is only allowed if an insulated flue pipe (insulation min. 4 cm with
mineral or rock wool (AGI Q 132)) is mounted.
*3 This value applies for a niche installation, without the influence of the glass pane's front radiation to the
sides.
*4 This value applies for a ceiling flammable/to be protected and a minimum lateral wall-distance of the
fireplace of 150 mm.
5
Colin
Jay
1856 mm
1839 mm
818 mm
846 mm
591 mm
626 mm
325/373 kg
371/391 kg
180 mm
180 mm
8 kW
9 kW
11 kW
13 kW
4 kW
4,5 kW
98 – 225 m³
114–305 m³
7,74 g/s
7,21 g/s
298 °C
341 °C
12
12
10
10
800 mm
in testing
0mm (*1,
*3) / 150
in testing
mm
0 mm (*1)
in testing
540 mm
in testing
(*4)
in testing
Colin, Jay, Mel, Minh, Rikk, Sam
Mel
Minh
1861 mm
1659 mm
658 mm
470 mm
763 mm
474 mm
417 kg
239 kg/---
180 mm
150 mm
10 kW
5 kW
14 kW
7 kW
5 kW
2,5 kW
130–360 m³
48 -124 m³
8,4 g/s
5,0 g/s
339 °C
273 °C
12
12
10
10
800 mm
850 mm
0 (*1) / 15
800 mm
mm
0 (*1) / 15
0 mm
mm
630 mm
760 mm
800 mm
850 mm
Rikk
Sam
1736 mm
1639 mm
918 mm
786 mm
591 mm
530 mm
339/353 kg
327 kg
180 mm
150 mm
10 kW
6,5 kW
14 kW
9 kW
5 kW
3,5 kW
72 – 190 m³
130-360 m³
8,13 g/s
6 g/s
313 °C
326 °C
12
12
10
10
800 mm
in testing
150 mm
in testing
(*1)
0 mm (*1)
in testing
660 mm
in testing
in testing

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

JayMinhMelSamRikk

Inhaltsverzeichnis