6.2 Failure of the power suppl y
During a power failure, the control unit continues to remain active thanks to the battery.
In the event of a power failure, the control unit operates as follows:
Duration of the
power failure
Less than 1 minute
More than 1 minute

6.3 Undetermined error at the control panel

Upon starting up, certain information stored in the control unit is updated on the control panel (e.g. the
configuration).
If changes have been made to the control unit and the control panel unexpectedly shows an error, reset
the control panel by disconnecting and then reconnecting it. If the problem is still present, please contact
the service personnel.
7

Cleaning

Because cleaning intervals depend greatly on the installation location and operating hours, the times
stated in the following table can only be considered to be reference values. Basically, all of the following
components must be cleaned depending on their degree of contamination.
Cleaning the viewing window
Visual inspection of the burner bowl and grate, remove clinging deposits
Emptying of the ash box and cleaning of the combustion chamber
Replacement of the air filter
Cleaning of the flue gas ducts, flue gas collectors and exhaust duct blowers
Cleaning of the combustion chamber temperature sensor (only with a dry cloth)
Cleaning of the air quantity sensor (blowing clean the measuring wire)
Replace the battery
Inspecting all seals (door, ash box, grate, tank lid); replace as the case may be
Cleaning of the chimney as per the chimney sweep specialist
51
Operation before the
power failure
Phase Fire up
Phase Burning
OFF
Phase Fire up
Phase Burning
OFF
Operation after the power failure
The control unit continues operating normally.
The control unit tests the air temperature and
either continues operating in the Burning
phase or restarts in the Fire up phase.
OFF
The control unit continues operating normally.
The control unit tests the temperature of the
flue gases. If the flue gas temperature has
fallen below the value of PAR56, the fire
chamber restarts in the Fire up phase or
otherwise continues to operate in the Burning
phase.
OFF
english
2-3 days
2-3 days
7-14 days
1-2 months
Once a year
Once a year
Once a year
2 - 3 years
Once a year
Min. once a
year