000Book_RP350YDM.indb 29
000Book_RP350YDM.indb 29
Downloaded from
www.Manualslib.com
Precautionary measures with vacuum cleaners class H and M
The outside of the vacuum cleaner should be cleaned and wiped
down or should be treated with a sealing agent before being
removed from the dangerous area. All parts of the vacuum cleaner
must be considered to be contaminated when they are removed
from the danger area and suitable handling must be used to
prevent dust distribution.
Contaminated items
When carrying out maintenance or repair work, all contaminated
items which have not been adequately cleaned must be disposed
of. Such items must be disposed of in impermeable bags in ac-
cordance with the applicable regulations concerning the disposal
of such waste.
Testing the effectiveness of the vacuum cleaner
NOTE: In addition, the effectiveness of the vacuum cleaner class H
must be checked at least once a year.
There must be an adequate air exchange rate L in the room if the
exhaust air returns to the room. Further information can be taken
from your national regulations.
11 First aid in the event of a fault
Malfunctions cannot always be traced back to defects in the vacuum cleaner.
Fault
Possible cause
Reduction in suction
Filter contaminated
fl eece fi lter full
Container full
Nozzle, pipes or hose blocked
Vacuum cleaner will not start
Mains plug plugged in?
Mains power missing?
Mains cable OK?
Cover closed properly?
Water sensor switched off?
Vacuum cleaner in readiness for opera-
tion "AR"?
The vacuum cleaner does not start
Is the mains plug of the unit in the plug
when the tool is switched on in the
socket?
>AR< mode
Solenoid valve of compressed air auto-
matic switch-on* contaminated?
PE emptying and disposal bag is sucked
Position of rotary slider incorrect
against the fi lter
Vacuum cleaner classes M or H: with
Position of rotary slider incorrect
inserted paper fi lter dust in fi lter
Do not take any other action and contact the central customer service workshop.
manuals search engine
If the suction of the vacuum cleaner reduces and the cleaning
procedure of the folding fi lter cassettes increases, the suction
performance is not adequate (provided that the container is empty
and the fl eece fi lter bag has been replaced) then it is necessary to
replace the folding fi lter cassettes
(see short-form instructions
and Section
7.1).
10.1 Cleaning
NOTE
Acids, alkalis and solvents can corrode the vacuum cleaner
parts.
▷ Clean the container and accessories with water.
▷ Wipe the top section with a damp cloth.
▷ Allow the container and accessories to dry.
10.2 Repair
l DANGER!
▶ Inappropriately repaired vacuum cleaners present a danger
to the operator.
▶ Have repairs carried out by specialists, e. g. customer
service. Use only genuine spare parts.
NOTE
Remedy
Clean.
Change.
Empty.
Clean.
Set to "I" or "IR"
(see "2 Display and Operating
Elements").
Put the mains plug in the vacuum cleaner plug
socket
Flush the compressed air automatic switch-on* with
alcohol
Set rotary slider to ● position
emptying and disposal
bag").
Set rotary slider to ▲ position
fl eece fi lter
bag").
de
en
fr
es
pt
it
nl
da
sv
no
el
tr
pl
hu
cs
sk
ro
sl
hr
bg
(see "6.4 Inserting PE
(see "6.3 Inserting
en - 29
2015/03/06 15:11:51
2015/03/06 15:11:51

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rp 350ydh

Inhaltsverzeichnis