This electrical product, if installed in a shower
room or bathroom, must be situated so it
cannot be touched by persons making use of
the bath or shower.
Installing the switches and cables
1. Check that there are no buried pipes or
cables (e.g. Electricity, gas, water) behind
the switch location (in the wall or above
the ceiling).
2. Lay in the cable from the isolating switch to
the fan location via the on/off switch (see Fig.
E.
3. Lay in the cable from the isolating switch to
the point of connection to the mains supply.
WARNING:
CONNECTIONS TO THE ELECTRICITY
SUPPLY AT THIS STAGE.
4. Install the isolating switch and the on/off
switch, see Fig. E.
5. Make all connections within the isolating
switch, and the on/off if required.
Note: When installed in a bathroom all switches
must be of a pull cord type and must be situated
so that they can not be touched by persons
making use of the bath or shower.
For Australia only
These models are permanently connected to the
supply and operation is controlled by a remote
switch. Wire directly to the supply through an
approved 10A wall mounted surface switch with at
least 3mm clearance between contacts.
Preparing the hole
If working above ground level, appropriate safety
precautions must be observed.
WARNING: EYE PROTECTION MUST BE WORN
DURING
ALL
DRILLING
OPERATIONS.
If installing in a wall
1. Check there are no buried pipes or cables
in a wall or obstructions on the outside
(e.g. Electricity, gas, water).
2. Ensure that the centre of the hole is located
at least 145mm from the edges of the wall,
see Fig. A.
3. Mark on the centre of the duct hole.
4. Use this centre to draw a circle to suit the wall
duct (203mm diameter for a WK6/300 or
WK6/450).
If core drill equipment is available
5a.
Use
as
directed
manufacturer.
If core drill equipment is not available
5b. Drill a centre hole right through the wall.
6. Cut the hole. Do not cut right through the wall
(the recommended method is to drill a series
of holes, close together, around the edge of
the cutting line and remove the brick between
the holes with a chisel).
DO
NOT
MAKE
AND
CHISELLING
by
the
core
7. Go outside and cut a hole in the outer wall,
repeating the process described above.
8. Fit the ducting. Ensure that the duct slopes
down away from the fan to allow drainage of
any incoming rain water to the outside.
9. Make good the hole. Allow for the mortar to
set before continuing with the installation.
If installing in a window
Obtain a ready cut pane with a correctly located hole,
184mm diameter, see Fig. A.
Preparing the fan for installation
1. For window mounting, use the two short
ladder strips supplied with the fan.
For wall mounting, use the longer ladder
ANY
strips supplied with the wall kit WK6/300 or
WK6/450.
2. Secure the two ladder strips to the outer grille
by positioning them over the hook moulding
and snapping them into position.
3. Ensure after fitting the hook moulding that the
gasket is in the correct position, see Fig. B.
4. Insert the two screw covers in the two fixing
holes in the outer grille.
Mounting the fan in the hole, Fig. C.
If working above ground level, appropriate safety
precautions must be observed.
Remove the back draught shutter/grille assembly by
pressing the release catches located on the sides of
the unit with a 6mm screwdriver or a coin, whilst
pulling the grille forward.
If installing with ladder strips
1. Hold up the outer grille to the outside wall or
window so that the hole in the outer grille is
aligned with the hole in the wall or window.
2a. If wiring from the rear, remove the fan's
terminal cover and rear entry knockout. Feed
the cable through the rear cable entry.
2b. If wiring from above, remove the fan's
terminal cover and feed the cable through the
top cable entry.
3. Hold the fan assembly to the inside of the wall
or window and guide the ladder strips from
the outer grille through the slots in the fan
assembly.
4. Insert the slotted screws into the pockets
around the ladder strip slots.
5. Tighten the screws carefully to make a good
seal, do not over tighten the screws.
6. Trim the ladder strips back to the required
length, if necessary remove any sharp edges.
If using screw fixings
drill
1. Hold the outer grille up to the outside of the
wall so that the hole in the outer grille is
aligned with the hole in the wall.
2. Mark the positions of the fixing holes in the
top right and bottom left corners.
3. Drill the holes and insert anchor fixings to suit
the wall.
4. Screw the outer grille securely in place. Do
not over tighten screws.