Ethernet/IP™ Klassen SAI-AU
Number
Name
Data Type
Access
Description
Configuration Control:
Number
Name
Data Type
Access
Description
Physical Link Object:
Number
Name
Data Type
Access
Description
Interface Configuration:
70
3
Configuration Control
Double Word DWORD
Get/Set
Bitmap for network configuration control
00 00 00 00
H
01 00 00 00
H
02 00 00 00
H
4
Physical Link Object
Struct of UINT, Padded EPath
Get
Path to Ethernet Link Object for this TCP/IP Interface object
02 00 20F6 24 01
H
5
Interface Configuration
Struct of 5 * UDINT, String
Get/Set
TCP/IP network interface configuration
4 Bytes
4 Bytes
4 Bytes
4 Bytes
4 Bytes
max. 48 Bytes, padded
to even number
Obtain IP configuration from non volatile
memory
Obtain IP configuration from BootP
server
Obtain IP configuration from DHCP
server
IP address
network mask
gateway address
name server 1
name server 2
domain name