Operating Temperature - Kaisai RG10A/BGEF Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für RG10A/BGEF:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating temperature

When your air conditioner is used outside of the following temperature ranges, certain safety
protection features may activate and cause the unit to disable.
Inverter Split Type
COOL mode
17°C - 32°C
Room Temperature
(62°F - 90°F)
0°C - 50°C
(32°F - 122°F)
Outdoor
Temperature
(32°F - 126°F)
(For special
tropical models)
Fixed-speed Type
COOL mode
Room
17°C-32°C (62°F-90°F)
Temperature
18°C-43°C (64°F-109°F)
-7°C-43°C (19°F-109°F)
Outdoor
(For models with low-temp cooling systems)
Temperature
18°C-52°C (64°F-126°F)
(For special tropical models)
NOTE: Room relative humidity less than 80%. If the air conditioner operates in excess of this
figure, the surface of the air conditioner may attract condensation. Please sets the vertical air
flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
To further optimize the performance of your unit, do the following:
Keep doors and windows closed.
Limit energy usage by using TIMER ON and TIMER OFF functions.
Do not block air inlets or outlets.
Regularly inspect and clean air filters.
HEAT mode
0°C - 30°C
(32°F - 86°F)
-25°C - 24°C
-15°C - 50°C
(-13°F - 75°F)
(5°F - 122°F)
(For models with
low temp. cooling
systems.)
0°C - 52°C
DRY mode
10°C - 32°C
(50°F - 90°F)
0°C - 50°C
(32°F - 122°F)
0°C - 52°C
(32°F - 126°F)
(For special
tropical models)
HEAT mode
0°C-30°C
(32°F-86°F)
-7°C-24°C
(19°F-75°F)
59
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
When outside
temperature is below 0°C
(32°F ), we strongly
recommend keeping the
unit plugged in at all
time to ensure smooth
ongoing performance.
DRY mode
10°C-32°C (50°F-90°F)
11°C-43°C (52°F-109°F)
18°C-43°C (64°F-109°F)
18°C-52°C (64°F-126°F)
(For special tropical models)