Installation; Mounting; Opening The Device / Electrical Connection; Cable Entries (Kle); Blanking Plugs - Eaton CROUSE-HINDS Serie Betriebsanleitung

Steckvorrichtungen für industrieanwendungen
Vorschau ausblenden Andere Handbücher für CROUSE-HINDS Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fig. 4
Item 1
Item 2
Item 3
Fig. 5
Item 1
Fig. 6
Item 3
Item 2
Item 3
Fig. 7
Item 2
Fig. 8
Item 2
Downloaded from
www.Manualslib.com
Plug and socket system for industrial use 63 A,
3-pole, 4-pole and 5-pole, GHG 524
6
For the mounting and operation, the
respective national regulations as well
as the general rules of engineering will have
to be observed.
Item 3
6.1
The wall sockets can be mounted without
opening their enclosure.
View 1
In case the wall sockets are mounted directly
onto the wall, they may rest evenly only at the
L2
respective fastening points. The chosen screw
L1
L3
shall match the fastening hole (see dimensional
drawing) and it must not damage the hole (e. g.
PE
use of a washer). The device shall be fastened
diagonally with at least 2 screws.
Item 2
The wall sockets and flange sockets shall
be mounted so that the plug hole does not
point upwards.
6.2
The electrical connection of the device may
only be carried out by skilled staff.
Item 2
Item 1
The insulation of the conductors shall
reach up to the terminal. The conductor
itself shall not be damaged.
Taking into account the respective regulations,
the properly bared conductors of the cables
Item 3
shall be connected.
The electrical connection of the plugs is
established as shown in fig. 4 and 5:
Item 1
The plug insert (item 2, fig. 5) is removed
Item 3
from the pin bushing (item 1, fig. 5), after the
fastening screws (item 3, fig. 4) have been
unscrewed.
Thereafter, the plug insert can be connected to
the connections of the plug pins
(see view 1, fig. 5).
Attention: When the fastening screws
(item 3, fig. 4) get lost, they will have
to be replaced by similar screws or to be
ordered directly from the manufacturer.
Item 4
Item 1
Item 1
manuals search engine

Installation

Mounting

Opening the device /
Electrical connection
Assembly is made in inverse order, after the
cable has been connected.
The inlets are electrically connected as
shown in fig. 6 to 8:
Fig. 6: After unscrewing the two screws item 3,
the plug insert item 2 is removed from the
flange item 2.
Fig. 7: Now the connecting leads item 4 can be
connected to the terminal L1... and PE als of
the plug insert item 2 as described in point 6.2.
Fig. 8: Finally, using the self-cutting screws
item 3, the plug insert item 2 is screwed into
the flange, observing its proper position.
The connectible min. and max. conductor
cross-sections shall be observed
(see technical data).
All screws and/or nuts of the supply
terminals, also of those remaining vacant,
shall be tightened down.
The supply terminals are designed for the
connection of copper conductors. If multi- or
fine-wire connecting cables are used, the wire
ends will have to be handled in acc. with the
applicable national and international rules
(e.g. use of sleeves for strands).
6.3
Cable entries (KLE);
blanking plugs
6.3.1 Plug and socket
Flexible cables shall be used with trumpet-
shaped cable glands or other suitable
entries with additional pull-relief.
When using cable entries with a lower IP
protection than that which applies to the device
(see page 7 , technical data), the IP protection of
the whole device will be reduced.
The mounting directives applicable to the cable
entries used shall be observed. Unused holes
shall be closed with a blanking plug in order to
establish the minimum protection category.
In case of sealing inserts that are cut out, it
shall be ensured that the insert is properly
adapted to the cable diameter. Care has to
be taken that when fitting the cable entries,
sealing inserts appropriate to the cable
diameter are used.