Operation
The subsequent table shows the signal curves during Touch Probe/Tool Setter activation:
Signal from control
Touch Probe
ON/OFF
on Pin 6
Touch Probe
Signal from control
Tool Setter ON/OFF
on Pin 7
Tool Setter
4.2.4
Optical Indicators
Indicator
LED Touch Probe
LED Tool Setter
Status LED
Battery LED
70
Flash-Pattern
green blinking
green
red blinking
red-green blinking
green blinking
green
red blinking
red-green blinking
green
orange
red
red
Delay time for switch over
Meaning
•
Receiver sends ON signal for Touch Probe (Fig. 27)
•
No signals from Touch Probe
•
Status: "READY"
•
Receives signals from Touch Probe
•
Error code, refer to chapter 4.2.5
•
Receiver sends OFF signal for
Touch Probe (Abb. 27)
•
Receiver sends ON signal for Tool Setter (Fig. 27)
•
No signals from Tool Setter
•
Status: "READY"
•
Receives signals from Tool Setter
•
Error code, refer to chapter 4.2.5
•
Receiver sends OFF signal for
Tool Setter (Fig. 27)
•
Status: "READY"
•
Receives signals from Touch Probe/Tool Setter
•
Status: "PROBE"
•
Touch Probe/Tool Setter deflected
•
Inactive status of Touch Probe/Tool Setter
•
Status: "LOW BATTERY"
•
Touch Probe/Tool Setter transmits low battery warning
•
Change measurement system batteries!
IRR61.00