Operation
The subsequent table shows the signal curves during Touch Probe/Tool Setter activation:
Signal from control
Touch Probe
ON/OFF
on Pin 6
Touch Probe
Signal from control
Tool Setter ON/OFF
on Pin 7
Tool Setter
4.2.4
Optical Indicators
Indicator
LED Touch Probe
LED Tool Setter
Status LED
Battery LED
70
Flash-Pattern
green blinking
green
red blinking
red-green blinking
green blinking
green
red blinking
red-green blinking
green
orange
red
red
Delay time for switch over
Meaning
Receiver sends ON signal for Touch Probe (Fig. 27)
No signals from Touch Probe
Status: "READY"
Receives signals from Touch Probe
Error code, refer to chapter 4.2.5
Receiver sends OFF signal for
Touch Probe (Abb. 27)
Receiver sends ON signal for Tool Setter (Fig. 27)
No signals from Tool Setter
Status: "READY"
Receives signals from Tool Setter
Error code, refer to chapter 4.2.5
Receiver sends OFF signal for
Tool Setter (Fig. 27)
Status: "READY"
Receives signals from Touch Probe/Tool Setter
Status: "PROBE"
Touch Probe/Tool Setter deflected
Inactive status of Touch Probe/Tool Setter
Status: "LOW BATTERY"
Touch Probe/Tool Setter transmits low battery warning
Change measurement system batteries!