Herunterladen Inhalt Inhalt Diese Seite drucken

Tool Setter Calibration; Optical Status Display - m&h IRP60.00 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operation
3.2.6

Tool Setter Calibration

Due to the short delay between triggering and reading the axis position, calibration of the Tool Setter is required.
During calibration the following is determined:
Switching characteristic of the Tool Setter in different machine axes,
Effective length of the Tool Setter
Response time of the Tool Setter in relation to the NC.
Calibration of the Tool Setter is performed using control specific calibration cycles.
Tool Setter Calibration
3.2.7

Optical Status Display

Subsequent table gives an overview of the blinking patterns of the LED (Fig. 19) and their meaning.
LED permanently blue (approx. 5s)
LED blinking green
LED blinking green/red
LED blinking orange
LED permanently red
Optical Status Display
62
INFORMATION
Calibration pin
(35.20-CP)
Tool Setter initializes after inserting batteries
Tool Setter is transmitting signals
Low battery warning
Stylus deflected
Error
IRT65.00