Herunterladen Inhalt Inhalt Diese Seite drucken

Assembly - Installation - Helios B AMD Serie Montage- Und Betriebsvorschrift

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation and Operating Instructions
EN
m
WARNING
nm
Meduim-Pressure Axial Smoke Extraction Fans – B AMD F300/F400
Installation examples – Vertical F300/400: Smoke extraction fan B AMD.. with accessory parts
Extension duct
VR
B AMD..
Mounting ring
vertical MRV..
Vibration damper SDD..
for pressure load
Dimensions B AMD
A
3 .1
Assembly – Installation
m WARNING
The fan can tip over and crush limbs during installation!
Note transportation diagram and centre of gravity! Wear protective footwear .
All occupational safety regulations, installation conditions and declarations of performance (DIBt technical approval)
must be observed for assembly and installation!
The smoke extraction fans must be positioned and installed so that inspection, maintenance and repair work can be
carried out easily and safely.
Installation conditions
VA:
Suitable for "vertical installation"
HA:
Suitable for "horizontal installation"
LB:
For "Ventilation mode" -20 °C to +60 °C
IB:
Can be installed in "Fire area"
Fan without insulating layer, the cooling air duct must be insulated inside the smoke extraction area
AB (WG): "Outside the fire area, thermally insulated"
In sufficiently ventilated rooms, fan with insulating layer F300 L60 or F400 according to DIN 4102-4
IF:
"Outside" if it is ensured that precipitation cannot penetrate the smoke extraction fan
Fig .3
Vibration damper SDZ..
for tensile load
Mounting ring
vertical MRV..
Extension duct
VR
B AMD..
Fig .5
F
6
B AMD
Ø
A
B
C
D
E
315 240
*
317 356 381
355 303
*
357 395 415
400 303
*
402 438 471 12x Ø9.5
450 378
*
452 487 519 12x Ø 9.5
500 378
*
502 541 570 12x Ø 9.5
560 480
*
562 605 636 16x Ø 11.5
630 555
*
632 674 719 16x Ø11.5
710 555
*
713 751 799 16x Ø 11.5
800 585
*
804 837 897 24x Ø 11.5
900 675
*
905 934 997 24x Ø 11.5
1000 675
*
1005 1043 1097 24x Ø 11.5
1120 810
*
1128 1174 1216 24x Ø 11.5
* Dim. B motor protrusion (mm) depends on type and motor
Fig .4
F
8x Ø 9.5
8x Ø 9.5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis