Herunterladen Diese Seite drucken

Baumer OXE7.E15T-11148276 Kurzanleitung

Optoelektronische sensoren

Werbung

Optoelektronische Sensoren
Photoelectric sensors
Détecteurs opto-électroniques
OXE7.E15T-11148276
Kanten-Sensoren
Edge sensors
Détecteur de bords
11148276
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Canada
Italy
Baumer Inc.
Baumer Italia S.r.l.
CA-Burlington, ON L7M 4B9
IT-20090 Assago, MI
Phone +1 (1)905 335-8444
Phone +39 (0)2 45 70 60 65
China
Singapore
Baumer (China) Co., Ltd.
Baumer (Singapore) Pte. Ltd.
CN-201612 Shanghai
SG-339412 Singapore
Phone +86 (0)21 6768 7095
Phone +65 6396 4131
Denmark
Sweden
Baumer A/S
Baumer A/S
DK-8210 Aarhus V
SE-56133 Huskvarna
Phone +45 (0)8931 7611
Phone +46 (0)36 13 94 30
France
Switzerland
Baumer SAS
Baumer Electric AG
FR-74250 Fillinges
CH-8501 Frauenfeld
Phone +33 (0)450 392 466
Phone +41 (0)52 728 1313
Germany
United Kingdom
Baumer Ltd.
Baumer GmbH
DE-61169 Friedberg
GB-Watchfield, Swindon, SN6 8TZ
Phone +49 (0)6031 60 07 0
Phone +44 (0)1793 783 839
India
USA
Baumer India Private Limited
Baumer Ltd.
IN-411038 Pune
US-Southington, CT 06489
Phone +91 20 2528 6833/34
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
1/4
OXE7.E15T-L82E.SIMD.7AI
Downloaded from
www.Manualslib.com
Abmessungen
Dimensions
26
4,3
4,5
M12 x 1
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
Technische Daten
Messbereich (Breite)
48 ... 72 mm
Messbereich (Abstand)
100 ... 150 mm
Messfrequenz
159 ... 625 Hz
1) 2)
kleinste erfassbare
0,7 mm
Stufe
Betriebsspannungsbe-
15 ... 28 VDC
reich +Vs
1)
Stromaufnahme max.
150 mA
(ohne Last)
Ausgangssignal
4 ... 20 mA /
0 ... 10 VDC
Schaltausgang
Gegentakt
verpolungsfest
ja, Vs zu GND
kurzschlussfest
ja
Fremdlichtsicherheit
< 35 kLux
Arbeitstemperatur
-20 ... +50 °C
Schutzart
IP 67
Technische Änderungen vorbehalten
manuals search engine
Dimensions
Elektrischer Anschluss
BN
GN
LED
YE
GY
RS 485
WH
push-
PK
pull
RD
BU
Class 2, UL 1310, see FAQ
1)
CLASS 1 LASER
2
19
55
Complies with 21 CFR 1040.10 and 1040.11
except for deviations pursuant to laser
notice No. 50, dated June 24, 2007
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technical data
measuring range (width)
measuring range (distance)
measuring frequency
smallest detectable step
voltage supply range +Vs
1)
current consumption max.
(no load)
output signal
switching output
reverse polarity protection
short circuit protection
ambient light immunity
operating temperature
protection class
Technical specifications subject to change
Sous réserve de modifications techniques
Connection diagram
(2)
+Vs
Z
Z
(3)
analog
BN = Braun/brown/brun
(4)
GN = Grün/green/vert
out
YE = Gelb/yellow/jaune
(5)
alarm
GY = Grau/grey/gris
(1)
Rx/Tx-
WH = Weiss/white/blanc
(6)
PK = Rosa/pink/rose
Rx/Tx+
(8)
RD = Rot/red/rouge
sync in
Z
Z
(7)
0V
PRODUCT
IEC 60825-1/2014
Données techniques
48 ... 72 mm
Plage de mesure (Largeur)
100 ... 150 mm
Plage de mesure (Distance)
159 ... 625 Hz
Fréquence de mesure
1) 2)
0,7 mm
Plus petit palier détectable
15 ... 28 VDC
Plage de tension +Vs
150 mA
Consommation max. (sans charge)
4 ... 20 mA /
Signal de sortie
0 ... 10 VDC
push-pull
Sortie commutation
yes, Vs to GND
Protégé contre inversion polarité
yes
Protégé contre courts-circuits
< 35 kLux
Insensibilité à la lumière ambiante
-20 ... +50 °C
Température de fonctionnement
IP 67
Classe de protection
Schéma de raccordement
5
4
6
8
7
3
2
1
48 ... 72 mm
100 ... 150 mm
159 ... 625 Hz
1) 2)
0,7 mm
1)
15 ... 28 VDC
150 mA
4 ... 20 mA /
0 ... 10 VDC
push-pull
oui, Vs vers GND
oui
< 35 kLux
-20 ... +50 °C
IP 67
15.11.2017

Werbung

loading

Inhaltszusammenfassung für Baumer OXE7.E15T-11148276

  • Seite 1 • Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten. • Disconnect power before connecting the sensor. Baumer Electric AG · CH-8501 Frauenfeld • Mettre l`installation hors tension avant le raccordement du détecteur. Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144...
  • Seite 2 Allg. Sicherheitsbestimmungen Display & Panel General safety instructions CLASS 1 LASER Display & Panel PRODUCT Instructions générales de sécurité Affichage & panneau IEC 60825-1/2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No. 50, dated June 24, 2007 VORSICHT CAUTION ATTENTION...
  • Seite 3 OXE7.E15T-L82E.SIMD.7AI 15.11.2017 Downloaded from www.Manualslib.com manuals search engine...
  • Seite 4 mm 150 140 130 120 110 100 EDGE L RISE 0.0 mm mm 150 140 130 120 110 100 OXE7.E15T-L82E.SIMD.7AI 15.11.2017 Downloaded from www.Manualslib.com manuals search engine...