Herunterladen Diese Seite drucken

Relay - Feig Electronic OBID i-scan ID ISC.LRU2000 Montage / Installation

Vorschau ausblenden Andere Handbücher für OBID i-scan ID ISC.LRU2000:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OBID i-scan

2.7.2 Relay

A relay output is provided in the form of a changeover relay.
Terminal
Table 2-8: Relay output pin-outs
Notes:
• The relay output is configured for max. 24 V DC / 2 A.
• The relay output is intended for switching resistive loads only. If an inductive load is
connected, the relay contacts must be protected by means of an external protection
circuit.
FEIG ELECTRONIC GmbH
Downloaded from
www.Manualslib.com
®
Abbreviation
1
COM
Working contact
2
NC
Normally closed
3
NO
Normally open
U
ext.
Fig. 2-7: Internal and possible external wiring of the relay output
manuals search engine
Installation
Description
X9
2
3
Page 43 of 56
ID ISC.LRU2000
1
M60801-0de-ID-B.doc

Werbung

Kapitel

loading