2.7.2 Relay
A relay output is provided in the form of a changeover relay.
Terminal
Table 2-8: Relay output pin-outs
Notes:
• The relay output is configured for max. 24 V DC / 2 A.
• The relay output is intended for switching resistive loads only. If an inductive load is
connected, the relay contacts must be protected by means of an external protection
circuit.
FEIG ELECTRONIC GmbH
Downloaded from
www.Manualslib.com
®
Abbreviation
1
COM
Working contact
2
NC
Normally closed
3
NO
Normally open
U
ext.
Fig. 2-7: Internal and possible external wiring of the relay output