Startup

4.1 Interface configuration

4.1.1 RS485/RS422

Jumpers J7 – J8 are used to configure the asynchronous interface as an RS485 or R422 port.
Table 4-1: Configuration of the RS485/RS422 port
Any termination resistors needed can be enabled using jumpers J1 through J6.
Table 4-2: Termination resistors for RS485/RS422
FEIG ELECTRONIC GmbH
Downloaded from
www.Manualslib.com
®
Jumper
RS485
J7
closed
J8
closed
Jumper
Closed
J1
Pull-Up on RS4xx - B
J2
Pull-Down on RS4xx - A
J5
Termination resistor
RS4xx - A ⇔ RS4xx - B
J3
Pull-Up on RS422 - Z
J4
Pull-Down on RS422 - Y
J6
Termination resistor
RS422 - Y ⇔ RS422 - Z
manuals search engine
Installation
RS422
open
open
Open
without Pull-Up on RS4xx - B
without Pull-Down on RS4xx – A
without Termination resistor
RS485 - A ⇔ RS485 - B
without Pull-Up on RS422 - Z
without Pull-Down on RS422 –
Y
without Termination resistor
RS422 - Y ⇔ RS422 - Z