OBID i-scan

2.3.1 Cable glands

The cable glands are located on the underside of the housing. Fig. 2-2: Installation drawing shows
the arrangement, and Table 2-3: Cable glands for ID ISC.LRU2000 indicates which cable glands
should be used for the individual lines.
Cable gland
Table 2-3: Cable glands for ID ISC.LRU2000
FEIG ELECTRONIC GmbH
Downloaded from
www.Manualslib.com
®
6
1
2
Fig. 2-2 Installation drawing
Clamping
Size
1
M 16
2
M 16
3
M 16
4
M 16
5
M 12
6
M 16
7
M 16
8
M 12
9
M 25
manuals search engine
Installation
7
8
3
4
range
Description
[mm]
4.5 – 10
Antenna cable
4.5 – 10
Antenna cable
4.5 – 10
Antenna cable
4.5 – 10
Antenna cable
3.5 – 7
Supply voltage
4.5 – 10
In-/Outputs/Interface
4.5 – 10
In-/Outputs/Interface
3.5 – 7
In-/Outputs/Interface
9 – 17
Network connection (optional)