Tare In/Out; Lock/Unlock; Unit Switch; User Setup - Baxtran UCS Serie Benutzerhandbuch

Digitaler wägehaken mit hoher auflösung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ES
FR

7-3. TARE IN/OUT

In gross mode, press
If load is in motion, or negative, or out of Tare Range, tare is not allowed.
Tare will reduce the apparent overload range of crane scale. For example, if a
5000*2kg crane scale has a 1000kg container as its tare, the crane scale will overload
at a new weight of 4018kg (5000 – 1000 + additional 9 divisions).
In net mode, press

7-4. LOCK/UNLOCK

Press
Press

7-5. UNIT SWITCH

Press
If scale is tared, unit switch is not allowed.

8. USER SETUP

Press

8-1. AUTO-OFF TIMING

Press
Press
> Auto-Off Timing can be set to: 0 (disabled), 5 (5min), 15 (15min), 30 (30min), 60
(60min).
Auto-Off function maximizes crane scale's battery life against people's carelessness not to power off
crane scale when it's not working.
Auto-Off starts countdown timer when there's no action or load is stable. Any key pressing or motion
in load restarts countdown timer.
Press
20
Downloaded from
www.Manualslib.com
ENG
DE
to tare in. Shows TARE.
to tare out. TARE disappears.
to lock screen. Shows HOLD.
to unlock screen. HOLD disappears.
for 1s to switch unit in between kg, lb, and N.
at the same time for 1s to enter User Setup menu. SEtUP shows
and
to enter Auto-Off Timing. oFF – - shows.
to change timing value.
to confirm your selection and move to the next menu.