Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
The electronic unit O&O, model BSX/BR, to control the COLORADO series of automatic barriers, complies with the EEC directives 73/23 (Low
Voltage) and 89/336 (EMC) and allows installation in observance of the current safety rules and regulations.
- Complete for functioning (semiautomatic and automatic) and adjustment (working time, pause time and motor power) ranges.
- Flexible for the choice of options (pre-flashing, flash light output controlled directly by the control unit, output for a courtesy light).
- Safe in that it combines motor power adjustment and the output for the safety device with the reverser function.
- Easy to install thanks to the control LEDs, pull out terminals and to the serigraphy on the printed circuit.
SUPPLY VOLTAGE:
MOTOR OUTPUT:
ACCESSORIES POWER OUTPUT:
FLAShING LIGhT OUTPUT:
"USER" OUTPUT FOR ThE COURTESY LIGhT:
WORKING TIME:
1) Preparen línea arriba de la instalación un interruptor diferencial magnetotérmico de 10 A.
El interruptor debe garantizar una separación omnipolar con distancia de apertura de los contactos mínima de 3 mm.
2) Diferencien y separen los cables de "potencia" (secc. mínima 1,5 mm
3) Cortocircuiten las entradas N.C. (STOP, PhOTO) no utilizadas.
4) Coloquen en serie los eventuales contactos conectados a la misma entrada N.C.
5) Dispongan en paralelo todos los contactos conectados a la entrada START (N.A.).
6) Efectúen las conexiones como se indica a continuación, utilizando para ello la serigrafía presente el circuito impreso.
P
POWER LINE
230V
40
Input with internal protection (5x20 5A fuse)
N
50Hz
2
COURTESY LIGHT
Output active during movement and for a further 60
230V~
44
USER
seconds after each stop.
45
200Wmax
MOTOR
4
230V~
4 - Open; 5 - Common; 6 - Close
M
5
~
Connect the capacitor to terminals 4-6
500VA max
6
N.B. Swap connections on terminals 4-6 to reverse
direction
FLASHING LIGHT
N
11
230V~
See DIP4 and DIP2 for the functioning of this
output.
12
P
80Wmax
GND
24 V - OUTPUT
24V~
14
For powering the accessories
15
5Wmax
(Photocells, receiver, etc.)
24 VAC
Internal protection (5x20 500 mA fuse)
BSX/BR
Installation instructions
GENERAL

TECHNICAL FEATURES

230 V ~ 50 Hz
230 V ~ / 500 W Max.
24 Vac / 200 mA Max.
230 V ~ / 80 W Max.
230 V ~ / 200W Max.
4"÷90"
INSTALLATON
2
) de los de señal (secc. mínima 0,5 mm
CONNECTIONS
N.C.
N.O.
N.C.
N.C.
N.C.
- 4 -
PAUSE TIME:
POWER ADJUSTMENT:
WORKING TEMPERATURE:
IP NUMBER:
MAXIMUM OVERALL DIMENSIONS (mm):
2
).
green
REVERSER (see DIP5)
30
white
white
30 = +6Vdc
31
brown
brown
31 = signal input
32
32 = GND
PHOTOCELL
PhOTO
19
See DIP 6 for the functioning of this input.
E
8
GND
START
START
9
See DIP3 for the functioning of this input
E
8
GND
STOP
STOP
7
Using this push button/contact, all movement is stopped
E
immediately and the automatic reclosing function is
8
GND
excluded.
FCA
LIMIT SWITCHES
20
Opening limit switch (FCA) 20-22
FCC
21
Closing limit switch (FCC) 21-22
GND
22
N.B. Swap connections on terminals 21-22 to reverse
the limit switches
GB
4"÷110"
30÷98%
-15°÷ +60°
IP 54
115x225x105

Werbung

Inhaltsverzeichnis
loading