Herunterladen Inhalt Inhalt Diese Seite drucken

SATA SATAminijet 1000 K Betriebsanleitung Seite 136

Vorschau ausblenden Andere Handbücher für SATAminijet 1000 K:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operating instructions SATAminijet 1000 K/H RP/HVLP
EN
■ Purge paint channel with suitable cleaning solution.
■ For SATAminijet 1000 K: Flush material hose.
■ Screw connection nipple [2-12] to air connection [1-7].
■ Align air cap.
Horizontal spray [2-7]
Vertical spray [2-6]
8.2. Normal Operation
Connect spray gun
■ For SATAminijet 1000 K: connect material coupling [2-14] and
material hose [2-13].
■ For SATAminijet 1000 H: Mount RPS Adapter [2-11] and suction
cup [2-9].
■ Connect compressed air hose [2-8].
Fill with material
Notice!
When painting, only use as much material as is required for the specific
procedure.
When painting, maintain the necessary spray distance. After painting,
store or dispose of the material correctly.
For SATAminijet 1000 H
■ Fill suction cup (maximum 20 mm below top edge).
■ Screw screw-on lid [2-10] onto suction cup [2-9].
■ Screw suction cup onto adapter and via the QCC to the gun.
For SATAminijet 1000 K
■ Fill pressure tank and adjust pressure.
Adjust gun inner pressure
Notice!
The air micrometer [1-4] must be fully opened (vertical position) in the
settings [3-2], [3-3] and [3-4].
Notice!
The most precise way to adjust the gun inner pressure is with SATA
adam 2 [3-1].
136

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Sataminijet 1000 h

Inhaltsverzeichnis