8
COOLANT
Make sure that the cooling unit is turned off before disconnecting the liquid inlet and/or outlet hoses of the torch. The coolant is
harmful and can irritate the eyes and skin. Hot liquid may cause burns.
Risk of burns due to hot liquid Never drain the cooling unit immediately after use. The liquid contained inside is boiling, wait
until it cools down before draining.
max
min
COLD UNIT START-UP
For the first application, the pump start-up could be diffcult and generate a defect water flow. To start it correctly, it is recommended to use the
above hose and follow the instructions below to purge the system:
EXAGON / TITAN :
- Connect the quick coupling to the cold water outlet of the unit and place the other end in an empty container (ideally a bottle)
- Connect a torch to the product, then briefly squeeze the trigger to start the pump
- Once the pump is activated (container that fills with coolant), stop the product by turning off the main welding generator switch.
- Disconnect the start pipe, put the liquid back into the cooling unit and connect the beam correctly (see user manual of the welding generator).
TITANIUM / NEOPULSE / NEOFEED :
- Connect the quick coupling to the cold water outlet of the unit and place the other end in an empty container (ideally a bottle)
- In the « Settings/Cooling unit » menu, press the icon
- Once the pump activated (container that fills with coolant), stop the cooling unit by pressing one of the buttons on the HMI.
- Disconnect the starting pipe, put the liquid back into the cooling unit: your pump is started.
NEOCOOL / EXACOOL / WCU1KW C
M6x16 (x4)
M6 (x4)
FILLING
The operator must fill the tank up to its maximum indicated on the front of the cooling unit
but never under the minimum line or a warning message will be displayed on the screen.
It is essential to use a specific welding coolant with low electrical conductivity, being anticor-
rosive and anti-freezing. 052246).
The use of any other coolant (in particular the automotive standard coolant), can lead, by
electrolysis effect, to the accumulation of solid deposits in the cooling system, thus damaging
it and also blocking the circuit.
This recommended maximum level is essential to optimise the duty cycles of the cooled torch.
Any damage to the machine due to the use of a different coolant than the recommended type
will not be covered by the guarantee.
to start the start-up procedure.
M6x16 (x4)
M6 (x4)
EN
17