INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorised by the manufacturer should perform the installation of the welding equipment. During the installation, the
operator must ensure that the machine is disconnected from the mains. Connecting generators in serial or in parallel is forbidden.
EQUIPMENT DESCRIPTION (FIG-1)
The EXACOOL cooling unit is a system designed to cool the water cooled torches connected to your EXAGON 400CC/CV welding machine.
The NEOCOOL cooling unit is a system designed to cool the water cooled torches connected to your NEOPULSE 400/500 G welding machine.
The WCU1KW cooling unit is a system designed to cool the water cooled torches connected to your TITAN 400 / TITANIUM / NEOPULSE 320C
welding machines.
These devices are controlled directly by the welding machine via two connection cables (option):
Length
Section
1.8m
70mm²
5m
70mm²
70mm²
10m
95mm²
15m
95mm²
20m
The NEOCOOL and the WCU1KW C are equipped:
- with a water level protection making sure the filling is at the minimum level for the good functioning of the cooling system but also for a good torch
cooling.
- with a water flow protection in order to protect the torch against a blockage at the level of the water circuit or a damage of the torch connection.
The NEOCOOL, the EXACOOL and the WCU1KW C are equipped with a thermal protection to prevent the torch for overheating abnormally.
The recommended cooling system units are automatically detected by the machine.
EXACOOL / WCU 1kW C :
In the « Setup memory » menu of the wire feeder EXAFEED, the EXACOOL can be inhibited.
In the « Setup/CONFIG » menu of the TITAN 400, the WCU 1kW C can be inhibited.
NEOCOOL / WCU 1kW C :
NEOCOOL / WCU 1kW C :
On the HMI « Settings/Cooling unit » :
- AUTO: activation during welding and deactivation of the cooling unit 10 minutes after the end of welding.
- ON: the cooling unit is permanently controlled.
- OFF: the cooling unit is disabled.
- PURGE
: function dedicated to purging the cooling unit or filling the connection cables. The protections are then disabled.
DESCRIPTION OF THE EQUIPMENT (I)
1-
Water outlet
2-
Water inlet
3-
Tank level indicator
TROLLEY SET-UP (OPTION REF. 037328)
Warning! Do not connect the cooling unit whilst the welding machine is switched on.
EXACOOL / WCU 1kW C
1
M6x12 (x4)
M6 (x4)
NEOCOOL / EXACOOL / WCU1KW C
Part number
037243
047617
047624
047631
038448
038455
(TITAN 400)
4-
Fuse
5-
Filling cap
6-
Harnesses pre-cables
7-
Starter pipe
NEOCOOL
(NEOPULSE 400/500G)
EN
M6x12 (x4)
M6 (x4)