Herunterladen Inhalt Inhalt Diese Seite drucken

Repairs And Maintenance; Maintenance And Wearing Parts - BWT THERO 90PRO Einbau- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
App screen
fault

5 Repairs and maintenance

5.1 Maintenance and wearing parts

You have purchased a product that is durable
and easy to service. However, all technical
equipment requires regular servicing so that it
continues to function properly.
If the product malfunctions during the warranty
period, contact your contract partner or the
installation company, and quote the unit type
and serial number.
Observe: Please also observe the pro-
visions in the operating manual of the
installed external pre-filter.
Before performing work on electrical
components or opening the housing,
it is mandatory that the mains plug
be pulled and both the water infeed
and the permeate line be closed off in
order to guarantee that the unit is volt-
age-free.
Whenever maintenance is performed,
the connection lines and the device
must be checked for damage.
Note: Only customer service may
replace the wearing parts (e.g. after a
faulty pump).
Error
Device not working
Cause
Pressure sensor for
permeate is defec-
tive or has no power
supply
Replacement of wearing parts:
Maintenance work:
Responsible: Recommended
General visual
Customer
inspection
Leak-tightness
Customer
inspection
Cleaning with a
Customer
damp cloth
Conductivity (with
Customer/
external measuring device)
service
Replacement of the
Customer/
external pre- filter
service
insert (particle filter
[ optionally available])
Replacement of the
Service
RO cartridge
Observe: In accordance with BVG A3
(VBG4), the unit must be tested for
electrical safety every 4 years.
The BWT THERO 90PRO reverse
osmosis unit is subject to the Pres-
sure Equipment Directive 2014/68/
EU from 27 June 2014. The RO unit
fulfils the requirements set forth in arti-
cle 3, section 3, and was designed and
manu factured according to the appli-
cable engineering good practices.
The BWT THERO 90PRO device
does not have a CE mark according
to article 6, section 5, of the direc-
tive 2014/68/EU, but the attached CE
Declaration of Conformity is valid.
Remedy
Check power supply
and, if necessary,
replace the pressure
sensor or inform
service staff.
maintenance
interval:
Monthly
Monthly
As necessary
At least once
per year
Depending on
the pre-filter
used
Once per year
(recommended)
24
EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis