2.2 DTG 230
1. Remove the upper casing of the boiler.
2. Take out the heater door.
3. Position the anti-smoke release thermostat inside the draught
diverter over the 3 pre-drilled holes and secure it with the screw
delivered with the kit.
4. Fit the anti-smoke release thermostat cable to the back plate on
the draught diverter using the clips provided.
5. Pull the cable to the front of the boiler, passing it through the
diaphragm type cable clip on the front plate.
Keep surplus cable outside the insulation in order to
prevent any contact with hot components (heating body,
draught diverter).
24/07/07 - 94866888 - 8502-4251F
2.2 DTG 230
1. Verwijder de bovenmantel van de ketel.
2. Verwijder de keteldeur.
3. Plaats de thermostaat terugslagbeveiliging aan de binnenzijde
van de trekonderbreker op de 3 voorgeboorde gaten, bevestig
hem met de met de set meegeleverde schroef.
4. Bevestig de kabel van de thermostaat terugslagbeveiliging op de
achterplaat van de trekonderbreker met behulp van de
meegeleverde clips.
5. Breng de kabel naar de voorkant van de ketel door de
kabeldoorgang van het voorpaneel.
Plaats het overtollige stuk kabel binnen de isolatie, om
ieder contact met de hete delen (verwarmingselement,
trekonderbreker) te voorkomen.