IMPORTANT
BEFORE CONNECTING THE APPLIANCE CHECK THAT THE DATA ON THE SERIAL PLATE CORRESPOND TO
THE ACTUAL ELECTRICAL SUPPLY.
THE SERIAL PLATE GIVING THE ELECTRICAL DATA REQUIRED IN THE INSTALLATION IS FOUND INSIDE THE
APPLIANCE ON THE TOP RIGHT-HAND SIDE.
THE INSTALLATION MUST BE MADE ACCORDING TO THE INSTRUCTIONS GIVEN IN THIS SECTION, BY
PROFESSIONALLY QUALIFIED PERSONNEL.
THE ELECTRICAL SAFETY OF THIS APPLIANCE IS ONLY GUARANTEED WHEN IT IS CONNECTED TO AN
EFFICIENT EARTHING PLANT AS PRESCRIBED BY EXISTING ELECTRICAL SAFETY REGULATIONS.
THIS FUNDAMENTAL SAFETY REQUIREMENT MUST BE VERIFIED AND, IF IN DOUBT, REQUEST A PRECISE
CONTROL OF THE PLANT BY PROFESSIONALLY QUALIFIED PERSONNEL.
THE CONSTRUCTOR DECLINES ALL RESPONSIBILITY FOR DAMAGES CAUSED BY THE DISRESPECT OF AN
EFFICIENT EARTHING OF THE PLANT.
THE APPLIANCE MUST ALSO BE FITTED WITH AN EQUIPOTENTIAL SYSTEM W HOSE EFFICIENCY MUST BE
VERIFIED ACCORDING TO EXISTING REGULATIONS.
THE USE OF ADAPTERS, MULTI-PLUGS, AND/OR EXTENSION LEADS IS STRICTLY PROHIBITED
1.0 PRELIMINARY CONTROLS
1.1 - GENERAL CONTROLS
1.1.1 - Control the appliance is perfectly level. Regulate the adjustable feet if necessary.
1.1.2 - Control that the plastic protective coating is removed from all external surfaces.
1.1.3 - Control that the interior is washed with warm water and a neutral soap.
1.1.4 - Control that the appliance is positioned as far as possible from heat sources.
1.1.5 - Control that the free air circulation around the motor compartment is not obstructed.
1.1.6 - Control that the locking keys are beyond the reach of children.
1.2 - CONTROL OF THE ELECTRIC SYSTEM
1.2.1 - Control the voltage and frequency of the mains distribution :
THEY MUST FALL WITHIN THE GIVEN VALUES V 230 + 10%
1.2.2 - Tighten all the screws that fix the wires to the electrical components ( vibrations during handling and transport
could have loosened them ).
1.2.3 - Check that there is a circuit breaker before the socket with an opening distance of the contacts equal to or over
3 mm.
1.2.4 - Turn the main switch to the OFF position where the power cable plug will be connected.
1.2.5 -Check the compatibility of the socket with the plug of the appliance. If necessary, have it changed by professionally
qualified personnel. The technician should also check that the cable section to the socket is adequate for the
absorbed power of the appliance.
Check that the plug is in the socket.
2.0 START-UP - CHECKS
After the above controls have been thoroughly completed the appliance may be started-up :
2.1.1 - Turn the main switch, connected to the power cable plug, to the ON position.
2.1.2 - Turn the switch of the appliance to the ON position.
2.1.3 - Visualize the SET POINT.
2.1.3.1 - Press the SET button on the electronic thermostat.
2.1.3.2 - Set the desired value, based on the type of product being stored.
2.1.3.3 – Position the shelve guides and the shelves at the desired positions inside the cabinet.
BEFORE INTRODUCING FOOD ALLOW THE APPLIANCE TO REACH STABLE OPERATING CONDITIONS.
3.0 DISPOSAL OF UNIT
To dispose of this appliance, before it is scrapped it must be rendered unoperational by removing the power cable,
eliminating all parts of the appliance that could constitute a hazard and invalidate the lock, hinge and any other closing
devices to avoid that children playing could be trapped inside or injured.