Herunterladen Diese Seite drucken

LGB 25802 Bedienungsanleitung Seite 20

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

64 = lighting button 9 (on only when loco is reversing)
65 = button 1 (on only when loco is reversing)
128 = lighting button 9 (on only when loco is
moving forward)
129 = button 1 (on only when loco is moving forward)
(depends on loco model, do not change, as functions
can be affected or destroyed)
CV52
Command for front lighting terminal (see CV51)
CV53
Command for rear lighting terminal (see CV51)
CV54
LGB configuration
Bit programming
Bit 1: hand-off function, 0 = off, 1 = on [0]
Bit 2: MTS Back-EMF, 0 = off, 2 = on [2]
Bit 3: analog Back-EMF, 0 = off, 4 = on [0]
Bit 4: load-dependent chuffs, 0 = off, 8 = on [8]
Bit 5: 0 = F1 constant, 16 = F1 flashing [0]
Bit 6: 0 = F2 constant, 32 = F2 flashing [0]
Bit 7: 0 = two chuffs/revolution, 64 = four chuffs [0]
Bit 8: automatic brake sounds, 0 = on, 128 = off [0]
To program, add the values for the individual Bits and
program the resulting function value. The values for
Bits 5-8 vary between locos. The values for your loco
can be read using the 55045 MTS PC Decoder
Programming Module.
Hand-off function on: When operating with 55015,
you can adjust direction and speed for two seconds after
selecting a moving loco without causing the loco to stop.
CV55
Reset factory pre-set values for CVs
Program:
6-55->
5-55->
CV56
Voltage for function terminal F2
(depends on loco model, do not change, as functions
can be affected or destroyed)
CV57
Command for function terminal F2 (see CV51)
CV58
Pause time (analog operation) (0.5 seconds x function
value)
When the polarity of the analog track voltage is
reversed, the loco waits for the programmed time
period, then accelerates in the new direction
CV59
F button for half-speed mode
If CV59 is programmed to a value between 1 and 8, the
respective function button will trigger the half-speed mode.
Function value 0: half-speed mode not active.
CV60
Back-EMF: Max. adjustment factor
Specifies the max. increase or decrease of voltage applied
during each time interval (programmed in CV61)
1 = small steps, 255 = large steps
The factory pre-set values of CV60 and CV61 are
optimized for LGB motors.
22
[128]
[64]
[10]
(1-32)
[5]
[15]
(0-255)
[0]
(0-8)
[0]
(1-255)
[4]

Werbung

loading

Diese Anleitung auch für:

Hsb-dampflok 99 6001-4 sound