Wireless-rückmeldeeinheit
Inhaltsverzeichnis

Werbung

4320
Januar 2018
Abbildung 22. Menüstruktur des Handterminals -
Konfiguration
2
Configure
Online
1 Overview
1 Guided Setup
2 Manual Setup
2 Configure
3 Alert Setup (see below)
3 Service Tools
4 Calibration (see below)
Manual Setup
1 Wireless
2 Device
3 Limit Switch Configuration
4 Mapping
5 Fault Behavior
6 Local User Interface
7 Power Module
8 Event Configuration
2‐2‐7
Power Module
8
1 Power Module Type
2 Voltage
3 Power Module Date
4 Battery Life
5 Reset Module Data
2
Configure
1 Guided Setup
2 Manual Setup
3 Alert Setup
4 Calibration
2‐4
Calibration
1 Calibration Date
6
2 Sensor Calibration
3 Output Assignment
1
HINWEISE:
1
NUR FÜR AUF/ZU-REGELUNG.
2
ELEMENTBEZEICHNUNG IST PROCESS (PROZESS) (ANSTELLE VON VALVE POSITION [VENTILSTELLUNG]) BEI DER PROZESSBERICHTERSTELLUNG (NUR IM ÜBERWACHUNGS- ODER
SCHALTMODUS).
3
ELEMENTBEZEICHNUNG IST LATCHING SWITCH (SCHALTERVERRIEGELUNG) (ANSTELLE VON SWITCH STATE [SCHALTERSTATUS]), WENN DER BETRIEBSMODUS LATCHING (VERRIEGELUNG)
LAUTET (NUR IM ÜBERWACHUNGS- ODER SCHALTMODUS).
4
NICHT VERFÜGBAR IM SCHALTMODUS.
5
OVERRIDE LOCKED OUT (EINGRIFF GESPERRT) UND MODE CHANGED LOCKED OUT (MODUSÄNDERUNG GESPERRT) WERDEN BEI DER ÜBERWACHUNGSOPTION NICHT ANGEZEIGT.
6
WENN AKTIVIERT, WIRD DER ALARM NOT CALIBRATED (NICHT JUSTIERT) DURCH CALIBRATION DATE (JUSTAGEDATUM) ERSETZT.
7
NUR VERFÜGBAR BEI ÜBERWACHUNG.
8
DAS MENÜ POWER MODULE (BATTERIE) WIRD NICHT ANGEZEIGT, WENN EINE EXTERNE SPANNUNGSVERSORGUNG INSTALLIERT IST.
32
2‐2
1
2‐2‐6
Local User Interface
1 Calibration Locked Out
2 Override Locked Out
5
3 Mode Change Locked Out
5
4 LUI language
2‐2‐5
Fault Behavior
1 Active Fault Conditions
2 Enable Fault Conditions
3 Fault Behavior Details
4 Mode
2‐3
Alert Setup
1 Cycle Counter
2 Switch State Alerts
3 Switch Response Alerts
4 Controller Alerts
2‐3-4
Controller Alerts
1
1 Mode Alerts
2 Tracking Alerts
4
3 Close Time Alerts
4
4 Open Time Alerts
4
2‐1
Guided Setup
1 Device Setup
2 Configure Alerts
3 Join Device to Network
4 Configure Publishing
2‐2‐1
Wireless
1 Network ID
2 Join Device to Network
3 Broadcast Information
2‐2‐2
Device
1 Identification
2 Structure
3 Device Variable Properties
4 Discrete Variable Properties
2‐2‐3
Limit Switch Configuration
1 Valve Position
2
2 Switch State
3
3 Opened/High Trip Point
4 Closed/Low Trip Point
5 Deadband
6 Edit Parameters
2‐2‐4
Mapping
1 Set to Defaults
1
2 Primary
3 2nd
4 3rd
5 4th
6 Warning Information
1
1
2‐3-3
Switch Response Alerts
1  States (ref):
2 Transition Alert
3 Transition Dwell Alert
4 Transition Dwell
5  Configure:
6 Enable 'In Transition'
7 Enable 'Transition Dwell'
8 Transition Dwell Threshold
Betriebsanleitung
2‐2‐1-3
Broadcast Information
1 Tailor Burst Configuration
2 Set all Burst Messages to Default
3 Hardware Triggering
4 Message 0
5 Message 1
6 Message 2
2‐2‐2-1
Identification
1 Tag
2 Long Tag
3 Date
4 Description
5 Message
6 Polling Address
2‐2‐2-2
Structure
1 Snap Acting Control
2 Latching Mode
3 Application Mode
4 Configure Structure
5 Operational Options
6 Tracking Debounce
6 Count
2‐2‐2-4
Discrete Variable Properties
1 Switch State Properties
2 Set Point Properties
Device Variable Properties
1 Reporting Precision
2 Scaled Position Properties
2‐3-1
Cycle Counter
1  States (ref):
2 Cycle Counter Alert
3 Accumulated Count
4 Reset Accumulated Count
5  Configure:
6 Enable Cycle Count Alert
7 Cycle Trip Point
2‐3-2
Switch State Alerts
1
1  States (ref):
2 Switch Latched
3 Opened/High Limit Tripped
4 Closed/Low Limit Tripped
5  Configure:
6 Enable 'Latched' Alert
7 Enable 'Opened/High' Alert
8 Enable 'Closed/Low' Alert
D103621X0DE
1
7
1
2‐2‐2-3