Herunterladen Inhalt Inhalt Diese Seite drucken

IKEA MÖJLIG Gebrauchsanleitung Seite 12

Vorschau ausblenden Andere Handbücher für MÖJLIG:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH
The connection of the cooktop to the gas
pipe network or gas cylinder must be made
by means of a rigid copper or steel pipe
with fittings complying with local regula-
tions, or by means of a continuous surface
stainless steel hose complying with local
regulations.
If you see any abnormalities do not re-
pair the pipe, contact local After Sales
Service (refer to the Service chapter).
The connection must be installed correctly,
fixed into hob connection pipe. Otherwise it
will cause leakage of gas
Warning! Once the installation is
complete, check the perfect seal of
every pipe fixing. Use soapy water, never
flame.
Electrical connection
The electrical work necessary to install the
appliance must be done by a qualified
electrician or competent person, according
to the current regulations.
Before connecting, check that the nominal
voltage of the appliance stated on the rat-
ing plate, corresponds to the available sup-
ply voltage. Also, check the power rating of
the appliance and ensure that the wire is
suitably sized to suit the appliance power
rating (refer to the Technical data chapter).
The rating plate is located on the lower cas-
ing of the hob.
The appliance is supplied with a connection
cable. This has to be provided with a prop-
er plug, able to support the load marked on
the identification plate (refer to the Techni-
cal data chapter).
The plug has to be fitted in a proper socket.
If connecting the appliance directly to the
electric system, it is necessary that you in-
stall a double pole switch between the ap-
pliance and the electricity supply, with a
minimum gap of 3 mm between the switch
contacts. The double pole has to be of a
type suitable for the required load in com-
pliance with the current rules.
The connection cable has to be placed in
order that, in each part, it cannot reach a
90 °C temperature. The blue neutral cable
must be connected to the terminal block
marked with "N". The brown (or black)
phase cable (fitted in the terminal block
contact marked with "L") must always be
connected to the live phase.
Electrical Requirements
The manufacturer declines any liability if
these safety measures are not observed.
This hob is designed to be connected to a
230 V 50 Hz AC electrical supply.
Before switching on, make sure the electrici-
ty supply voltage is the same as that indica-
ted on the hob rating plate. The rating plate
is located on the bottom of the hob.
The hob is supplied with a 3 core flexible
supply cord.
Upon completion there must be no cut, or
stray strands of wire present and the cord
clamp must be secure over the outer sheath.
Replacement of the connection cable.
Warning! The replacement of electric
cable must be carried out exclusively
by the After Sales Service or by personnel
with similar competencies, in accordance
with the current regulations.
If the connection cable must be replaced,
only a type H05V2V2-F T90 cable must be
used. The cable section must be suitable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown (or
black) phase wire.
Gas setting conversion
This model is designed for use with
natural gas but can be converted for
use with butane or propane gas providing
the correct injectors. The injectors not sup-
plied with the appliance have to be or-
dered from After Sales Service (refer to the
Service chapter).
For data concerning injector replacement,
refer to the chapter Technical data
12

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis