Herunterladen Inhalt Inhalt Diese Seite drucken

Specific Safety Instructions; Before Use; Connecting To A Compressed Air Source - Parkside PDRP 6.2 B2 Originalbetriebsanleitung

Druckluft-reinigungspistole
Vorschau ausblenden Andere Handbücher für PDRP 6.2 B2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 44
Keep work area clean and well lit . Cluttered or
dark areas invite accidents . This enables better
control of the compressed air cleaning gun,
especially in unexpected situations .
Have the compressed air cleaning gun serviced
by a qualified repair technician using only
original replacement parts . This ensures that the
safety of the compressed air cleaning gun is
maintained .
Keep children and bystanders away while
operating the compressed air cleaning gun .
Distractions can cause you to lose control of the
compressed air cleaning gun .
Dress properly . Do not wear loose clothing or
jewellery . Keep your hair, clothing and gloves
away from moving parts . Loose clothes, jewel-
lery or long hair can be caught in moving parts .
Wherever possible, use a condensate separator
or drain the condensate (water) from the hoses
and tubing regularly before and during the use
of the compressed air cleaning gun .
NOTE!
An undersized compressed air system will
reduce the efficiency of your compressed air
cleaning gun .
Do not point the compressed air cleaning gun
at people or animals .

Specific safety instructions

Do not use force when operating the trigger
Make sure that all parts are securely mounted
before using the compressed air cleaning gun .
Wear the necessary protective clothing when
working with the compressed air cleaning gun,
in particular ear muffs, protective goggles and
work gloves .
36 
GB │ MT

Before use

NOTE
The appliance may only be operated with
cleaned compressed air and may not exceed
the maximum working pressure of 6 .2 bar
at the appliance . The compressor must be
fitted with a pressure reducer to regulate the
working pressure .
Note that the maximum working pressure
may not be exceeded . An excessive working
pressure does not mean increased output;
it merely increases the air consumption and
accelerates appliance wear . Always comply
with the technical information .
Connecting to a compressed air
source
NOTE
Before connecting the compressed air source,
the correct working pressure (3–6 .2 bar)
must be fully reached, and
make sure that the trigger
Pull the supply hose connector over the quick-
release fastener on the connector nipple
it clicks into place .
NOTE
To ensure that you can regulate the air
pressure, the compressed air source must be
.
equipped with a pressure reducer .
is not actuated .
until
PDRP 6.2 B2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis