Herunterladen Inhalt Inhalt Diese Seite drucken

Daikin J serie Installationshandbuch Seite 10

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39
Mounting Installation Plate
Ensure that the wall is strong enough to withstand the weight
of the unit. Otherwise, it is necessary to reinforce the wall
with plates, beams or pillars.
Use the level gauge for horizontal mounting, and fix it with 5
suitable screws for FTYN25/35LV1B and 7 suitable screws
for FTYN50/60LV1B.
In case the rear piping draws out, drill a hole 65mm in
diameter with a cone drill, slightly lower on the outside wall
(see figure).
FTYN25/35LV1B
Mounting plate fi xing screw
FTYN50/60LV1B
Mounting plate
fi xing screw
Recommended Mounting Plate Retention Spots
And Dimensions
FTYN25/35LV1B
«
Recommended mounting plate
retention spots (5 spots in all)
166
54.5
153.8
263
51.9
Liquid pipe end
FTYN50/60LV1B
«
Recommended mounting plate
retention spots (7 spots in all)
190
45
91
Liquid pipe end
580
45
1065
Mounting plate
Mounting plate
Use tape measure as shown.
Position the end of a tape
measure at
Ñ
184
181.7
55.5
800
Gas pipe end
All dimensions are in mm
173
Gas pipe end
219
48
All dimensions are in mm
Hole With Cone Drill
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of the installation
plate (Engage the two hooks at the rear top of the indoor unit
with the upper edge of the installation plate). Ensure that the
hooks are properly seated on the installation plate by moving
it to the left and right.
How To Attach The Indoor Unit
Hook the claws of the bottom frame to the mounting plate.
How To Remove The Indoor Unit
Push up the marked area (at the lower part of the front grille)
to release the claws.
Front grille
When stripping the
ends of interconnecting
wires in advance, bind
right ends of wires with
insulating tape.
Water Drainage Piping
Through the
wall hole
The indoor drain pipe must be in a downward gradient for
Ø 65mm
smooth drainage. Avoid situations that are likely to cause
water to leak.
Drain hose
position
Water Drainage
leaking
Through the
wall hole
Correct
Ø 65mm
Drain hose
position
• Do not install the unit at altitude over 2000m for both
1-8
Inside
Outside
Wall embedded pipe
(Field supply)
Bottom frame
Hang indoor unit's hook here.
Wire guide
Water
Retention
Water
Water
leaking
Wrong
Wrong
! CAUTION
indoor and outdoor.
Caulking
Ø 65
Mounting plate
Clip
Mark (rear side)
Mounting plate
Interconnecting
wires
Water
End dipped
leaking
into water
Drain
Wrong

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis