Electrical connection

Commissioning
Fill the tank and flush it through until the water flows out without bubbling, otherwise the
temperature sensor and the bracket could be damaged and will need to be replaced. During
heating, expansion water may drip from the safety valve outlet. Monitor the first heating.
After installation, give the user the operating instructions and explain how the appliance works.

Operation

Please warn children that the water can get hot.
The water temperature can be adjusted from 25 ºC (I) to 75 ºC (III) using the knob. We recommend
the "e" setting, with a water temperature of approximately 55 ºC. Heat loss and build up of scale
are kept to a minimum at this setting.
The indicator lamp lights up during heating. The thermometer shows the approximate warm water
temperature.
Note: the thermometer does not deflect fully at maximum temperature settings.
Set the knob to d frost protection if the tank is not to be used for a long time.
To avoid frost damage to the appliance, the tank must be emptied fully by the after sales service if
the power supply is to be disconnected for a long time.
The tank must be disconnected from the power supply before any work is carried out on the water
supply.
Once the work is complete, follow the procedure for when the tank was first commissioned.
230V/50 60Hz
x1 Mains terminal
f1 Temperature limiter
s1 Temperature controller
h1 Indicator lamp
r1 Heating element 2kW
13