Wiring the DC-Input Power Source
Step 2
Identify the positive and negative feed positions for the terminal block
connection. The wiring sequence is Return to Return and negative to negative for
both the A feed wires and the B feed wires. The rear panel of the switch identifies
the positive and negative positions for both the A and B feed wires.
Using a 12- or 14-gauge wire-stripping tool, strip each of the four wires coming
Step 3
from the DC-input power source to 0.27 inch ± 0.05 inch. Do not strip more than
0.29 inches of insulation from the wire. Stripping more than the recommended
amount of wire can leave exposed wire from the terminal block plug after
installation.
Using the Catalyst 2924M XL DC Ethernet Switch
16
0.27" ± 0.05"
78-10499-01