Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Victron energy 12/3000 Anleitung

Phoenix inverter
Vorschau ausblenden Andere Handbücher für 12/3000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 65

8. TECHNICAL SPECIFICATIONS

Phoenix Inverter
INVERTER
Input voltage range (V DC)
Output
(1)
Cont. output power at 25°C (VA)
Cont. output power at 25°C (W)
Cont. output power at 40°C (W)
Cont. output power at 65°C (W)
Peak power (W)
Maximum efficiency (%)
Zero-load power (W)
GENERAL
Programmable relay
(4)
Protection
(2)
Common Characteristics
ENCLOSURE
Common Characteristics
Battery-connection
230 V AC-connection
Weight (kg)
Dimensions (hxwxd in mm)
STANDARDS
Safety
Emission / Immunity
Automotive Directive
1) Can be adjusted to 60Hz; 120V/60Hz on request
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non linear load, crest factor 3:1
4) Multipurpose relay which can be set for general alarm, DC undervoltage or genset start signal
function
20
12/3000
9,5 – 17
Output voltage: 230 VAC ± 2%
3000
(3)
2400
2200
1700
6000
92
20
Yes
Operating temp.: -40 to +65°C (fan assisted cooling)
Humidity (non condensing): max 95%
Material & Colour: aluminium (blue RAL 5012) Protection: IP 21
M8 bolts (2 plus and 2 minus connections)
Screw terminals 13mm² (6 AWG)
EN 55014-1, EN 61000-3-2 / EN 55014-2, EN 61000-3-3
24/3000
19 – 33
Frequency
3000
2400
2200
1700
6000
94
20
Yes
a – g
18
362x258x218
EN 60335-1, EN 60335-2-29
2004/104/EC
48/3000
38 – 66
50 Hz ± 0,1%
:
3000
2400
2200
1700
6000
95
25
Yes

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

24/300048/300024/500048/5000

Inhaltsverzeichnis