1.
RJ45, RJ11, RJ12, USB test connector
2.
Display
3.
„Test" button
4.
Function switching switch
5.
„10A" socket: 200mA - 10A
6.
"mA" socket: til 200mA
7.
USB test socket (removable)
8.
Cable test LED lighting
9.
"Hold" button
10.
"Light" (background lighting) button
11.
"V-Ω" socket
12.
"COM" (common) socket
13.
Cable testing LED line
14.
Test socket RJ45, RJ11, RJ12 (removable)
V — ... measuring
• Connect the black measurning wire to the „COM" socket and the red one to
the „V/Ω" socket.
• Set the function switch to the proper „V — ...
setting and connect the wires to the circuit.
Note:
• If you are unsure about the measured voltage range, set the function
switch to a higher range.
• If the LCD shows „1" , it means a really high value, and the range should
be set to a higher value.
V~ measuring
• Connect the black measurning wire to the „COM" socket and the red one to
the „V/Ω" socket.
• Set the function switch to the proper "V~ "
measuring setting and connect the wires to the circuit.Note:
• If you are unsure about the measured voltage range, set the function
switch to a higher range.
• If the LCD shows „1" , it means a really high value, and the range should
be set to a higher value.
A — ... measuring
• Connect the black measurning wire to the „COM" socket and the red one to
the „mA" socket (max. 200 mA) or connect the red one to the „10 A" socket
(max. 10 A).
• Set the function switch to the proper „A — ...
setting and connect the wires to the circuit.