Herunterladen Inhalt Inhalt Diese Seite drucken
Vorschau ausblenden Andere Handbücher für Metropol S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Assembly
Attention! The fitting must be installed, flushed and
tested after the valid norms.

Operation

The mixer is actuated by lifting the lever head.
Move to the left = hot water,
move to the right = cold water.
The flow is changed from bath to shower function
by pulling the knop at the upper side of the spout.
After shutting off the water flow, the mixer returns
automatically to the bath function.
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow 0,3 MPa:
Anti-pollution function:
Hansgrohe single lever mixers can be used toge-
ther with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 15.
Don't install a hot-water-barrier in combination with
flow-heater!
Fault
Mixer stiff
Mixer dripping
Diverter not operating
Hot water temperature too low
No cold water
Instantaneous water heater
starts up when cold water is
selected
English
max. 1 MPa
1,6 MPa
max. 80° C
65° C
approx. 27/23 l/min
14466XXX
31466000
31646000
32477000
Cause
- Cartridge defective, calcified
- Cartridge defective, sedimentation
- Water pressure to low
- Diverter defective
- Hot water limiter incorrectly set
- Crossflow
Install the ibox always above the bath-tup. If parts of
the ibox will broken, the water can flow in there!
166XXX/166000/166000/77000:
The safety devices must be checked once a year.
The non return valves must be checked regularly ac-
cording to DIN EN 1717 in accordance with national
or regional regulations (at least once a year).
Spare parts (see page 3)
1
handle Talis E²
1.1 screw cover
2
handle Fcus S
3
handle Metropol S
4
handle Talis S / Talis S²
5
handle Metris S
6
flange
7
flange
8
fixing screw (4)
9
sub plate
10
nut
11
cartridge cpl.
12
locking screw for handle
13
seal
14
diverter knob
15
sleeve
16
selector assy
17
screw M5 x 20 (4)
18
noise reduction
19
vacuum breaker
20
non return valve
21
extension 25 mm
22
extension 22 mm
XXX = Colors
000 chrome plated
880 satin chrome
Remedy
- Exchange cartridge
- Exchange cartridge
- Increase water pressure
- Exchange diverter
- Set hot water limiter
- Exchange cartridge
31692000
96338000
31793000
14895XXX