6.3 Switching off the engine
Before you switch off the generator, allow it to run
briefly with no consumers so that it can "cool
down"
Move the ON/OFF switch (7) to position "0"
Turn the petrol cock (4) to position "0".
Important. The generator is fitted with an over-
load cut-out.
This shuts down the 230V~ socket (3). You can
restart the socket (3) by pressing the overload cut-
out (6).
Important. If this happens, reduce the electric
power you are taking from the generator.
6.4 Connecting to earth
The generator must be earthed to prevent an electric
shock from electrical equipment. Connect a piece of
cable between the earth connection on the generator
and an external earth point.

7. Maintenance

Remove dust and dirt from the machine at regular
intervals. The best tools for cleaning are a fine
brush or a cloth
Do not use any caustic substances to clean the
plastic
Take the petrol mixture out of the generator if you
do not intend to use the generator for a lengthy
period of time
Important. Switch off the machine immediately
and contact your service station:
In the event of unusual vibrations or noise
If the engine appears to be overloaded or misfires
If the emissions are too dark or too light
The generator must be earthed to prevent an electric
shock from electrical equipment. Connect a piece of
cable between the earth connection on the generator
and an external earth point.
6
30.04.2003
7:16 Uhr
Seite 6

8. TECHNICAL DATA

Generator
Protection type
Continuous power
Maximum power
Rated voltage
Rated current
Frequency
Drive engine design
Displacement
Max. power
FuelMixture
Tank capacity
Consumption at 3/4 load
Weight
Sound power level LWA
Sound pressure level LWM
9. Circuit diagram STE 800
Description
Field coil
Rectifier
Secondary coil
Capacitor
Main coil
Load switch
Synchronous
IP 23
650 VA / 650 W
800 VA / 800 W/S2/15min
230 V / 1
2.8 A / 1
50 Hz
1-cyl. 2-stroke, air-cooled
63 cc
0.95KW / 1.3 hp
1:50 (2%)
4.0 l
approx. 0.7 l/h
20.5 kg
94 dB(A)
89 dB(A)
Symbol
FC
D1
SC
C
MC
AC Reset