Herunterladen Inhalt Inhalt Diese Seite drucken

Desoutter ELRT Serie Bedienungsanleitung Seite 12

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
6159939064_01
To reach the best performance, we recommend
to set the CVIL II controller parameters as
follows:
Type
Parameters
of joint
Speed
Hard
Pulse amplitude
Speed
Soft
Pulse amplitude
Decrease
No
speed
by 10%
too low
Decrease
pulse amplitude
by 10%
INSTALLATION
● See page 9.
Do not use the tool with total cable length
above 30m.
Tool must be used with its protective
cover on.
STANDARD TOOL DESCRIPTION
A
1
Ouput
2
Trigger
3
Reverse
4
LEDs
Target torque
Min.
Max.
%
20
40
%
40
70
%
100
%
100
Tighten your application
Final torque
target torque
Yes
Pulses are displayed
on CVIPC or on
controller display
Yes
too high
Number
of pulses
OK
Setup OK for the joint
12 / 96
Increase
No
pulse amplitude
by 10%
Yes
Speed < 100%
No
Increase
speed
by 10%
Increase
pulse amplitude
by 10%
09/2019
English

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis