5 5 5 5 Setup

Rack installation

Install the unit on a plane surface or in your rack. For 19" (483 mm) rack installation, 3 units are required.
When mounting the unit into the rack, please make sure that there is enough space around the device so
that the heated air can be passed on. Steady overheating will damage your device. You can fix the unit with
four screws M6 in the rack.

Cable connections

The console offers numerous, highly flexible possibilities for balanced or unbalanced connection of
professional audio equipment. To avoid interfering noise, switch off the mixer or set the channel fader and
output controls to minimum prior to connecting and disconnecting equipment. Be sure to use only high-grade
cables. The illustrations below show the wiring of these cables.
Connector
XLR, male.
XLR, female
6.3mm jack, stereo
6.3 mm jack, mono
RCA

Powering up

To protect your audio equipment, specifically your speakers, follow this power-up sequence: Set all output
volume controls of any equipment to minimum. Switch on your audio sources first, then the mixer. Always
switch on amplifiers last. Then turn up the volume control on your sources (if provided) and set the output
volume of the mixer to a low level. Turn up the volume controls of your amplifier(s) slowly. Make adjustments
to all volume settings as needed. For switching off, follow the inverse sequence: always switch off amplifiers
first, then the mixer and then the audio sources.
Caution!
• If the phantom power is switched on, no microphones with unbalanced output must be connected.
Otherwise these microphones may be damaged. During the stabilization phase (approx. 1 minute), you
must not change any connection.
• To prevent switching noise, only actuate the button +48V when the mixer is switched off or when
all output controls are set to minimum.
Structure
Balanced
Unbalanced
connection
connection
red = 2
red = 2
black = 3
shield = 1 + 3
shield = 1
red = 2
red = 2
black = 3
shield = 1 + 3
shield = 1
red = tip
red = tip
black = ring
shield = sleeve +
ring
shield = sleeve
red = tip
red = tip
black = ring
shield = sleeve
shield = n/c
red = tip
red = tip
black = sleeve
shield = sleeve
shield = n/c