220-240 V ~ Single-phase line
16A fuse or differential cir-
cuit breaker
Electrical outlet
2 poles + + e e a a r r t t h h
standard CEI 60083
length 1.50 m approx.
As a specialist, you alone are competent to install and connect up Atag
appliances.
Our guarantee therefore applies only and exclusively to
appliances which have been installed and connected up by
you in accordance with the provisions of current regulations.
Failure to meet this requirement would incur the fitter's liability and
release the Atag company from any liability.
Single-phase 20A Meter
220-240V ~ 50Hz
Power
supply cable
The appliance must be fitted correctly to guarantee electrical safety. During
fitting and maintenance operations, the appliance must be unplugged from
the electrical grid. Fuses must be switched off or removed.
The electrical connections are made before the appliance is installed in its

housing.

Ensure that:
- the electrical installation has sufficient voltage,
- the electrical wires are in good condition,
- the diameter of the wires complies with the installation requirements.
Your oven must be connected with a (standard) power cable with 3 conduc-
tors of 1.5mm2 (1 live + 1 neutral + earth) which must be connected to a 220-
240V ~ single-phase grid by means of a 1 live + 1 neutral + earth CEI 60083
standard power socket or via an all-poles cut-off device in compliance with
the installation rules.
Warning
The safety wire (green-yellow) is connected to the appliance's
and must be connected to the earth terminal of the electrical set-up.
It is necessary to allow disconnection of the appliance from the supply after
installation, unless the appliance incorporates a switch complying with 24.3.
The disconnection may be achieved by having the plug accessible or by
incorporating a switch in the fixed wiring in accordance with the wiring
rules. If the power cable is damaged, it must be replaced by the manufac-
turer, its after-sales service department or a similarly qualified person to
avoid danger.

installer's information

connecting up

electrical connection

terminal
GB 17

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ox3292cZx3211cZx3292c

Inhaltsverzeichnis