Herunterladen Inhalt Inhalt Diese Seite drucken

Pump Description - Lowara NSCE Montage-, Betriebs- Und Wartungshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
en - Original instructions
• Do not use this pump to handle liquids containing
abrasive, solid, or fibrous substances.
• Do not use the pump for flow rates beyond the
specified flow rates on the data plate.
Special applications
Contact the local sales and service representative in
the following cases:
• If the density and/or viscosity value of the pump-
ed liquid exceeds the value of water, such as wa-
ter with glycol; as it may require a more powerful
motor.
• If the pumped liquid is chemically treated (for ex-
ample softened, deionized, demineralized etc.).
• Any situation that is different from the ones that is
described and relate to the nature of the liquid.
3.2 Pump denomination
See
Figure 2
(page 318) for an explanation of the
denomination code for the pump and one example.
3.3 Nameplate
The nameplate is a metal label that is located on the
pump body or on drive lantern depending on model.
The name plate lists key product specifications. For
more information, see
Figure 1
The nameplate provides information regarding the
impeller and casing material, the mechanical seal
and their materials. For more information, see
3
(page 328).
IMQ or TUV or IRAM or other marks (for electric
pump only)
Unless otherwise specified, for products with a mark
of electrical-related safety approval, the approval re-
fers exclusively to the electrical pump.

3.4 Pump description

• Connection dimensions according EN 733 (mod-
els 32-125...-200; 40-125...-250; 50-125...-250;
65-125...-315;80-160...-315; 100-200...-400;
125-250...-400; 150-315...-400).
• Volute casing pump with back pull out power
end.
3.5 Material
The metallic parts of the pump that come in contact
with water are made of the following:
Material code
Material cas-
ing / impeller
CC
Cast iron/Cast
CB
Cast iron/
Bronze
CS
Cast iron/
Stainless steel
CN
Cast iron/
Stainless steel
DC
Ductil iron /
Cast iron
DB
Ductil iron /
Bronze
16
(page 313)
Figure
Standard/
Optional
Standard
iron
Standard
Standard
Standard
Standard
Standard
Material code
Material cas-
ing / impeller
DN
Ductil iron /
Stainless steel
NN
Stainless steel /
Stainless steel
RR
Duplex/Duplex
3.6 Mechanical seal
Unbalanced single mechanical seal acc. EN 12756,
version K.
3.7 Application limits
Maximum working pressure
Figure 4
(page 332) shows the maximum working
pressure depending on the pump model and the
temperature of the pumped liquid.
P
+ P
≤ PN
1max
max
P
Maximum inlet pressure
1max
P
Maximum pressure generated by the pump
max
PN
Maximum operating pressure
Liquid temperature intervals
Figure 4
(page 332) shows the working temperature
ranges.
For special requirements, contact the Sales and
Service Department.
Maximum number of starts per hour
kW
0.25
4.00
11
-
-
-
3.00
7.50
15
Starts
60
40
30
per
hour
Noise level
For the sound pressure levels of pump equipped
with standard supplied motor, see
333).
4 Installation
Precautions
WARNING:
• Observe accident prevention regula-
tions in force.
• Use suitable equipment and protec-
tion.
• Always refer to the local and/or na-
tional regulations, legislation, and co-
des in force regarding the selection of
the installation site, plumbing, and
power connections.
Electrical Hazard:
• Make sure that all connections are
performed by qualified installation
Standard/
Optional
Standard
Standard
Opzional
18.5
30
45
90
-
-
-
22
37
75
160
24
16
8
4
Table 7
(page

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

NscsNsc2

Inhaltsverzeichnis