Herunterladen Diese Seite drucken

Description Of Signs And Symbols; Fault Finding - AWELCO Bluemig 170 Bedienungsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10

DESCRIPTION OF SIGNS AND SYMBOLS

U
... (V)
0
EN 60974-1
U
... (V/Hz)
1
I
... (A)
2
I
(A)
1 max
FAULT
Wire isn't conveyed when
Feed roll is turning
Wire feeding in jerk or
erratic way
No arc
Porous welding seams
The machine suddenly stops welding
operations after an extended and heavy
duty use
1 ~
Single phase alternating voltage
3 ~
Three phase alternating voltage
Nominal open circuit voltage
Transformer-rectifier
Norm of reference
Flat characteristic
MIG-MAG wire feed welding
Nominal values of mains voltage
and frequency
Welding current
The
welding
unit's
absorbed current
1)
Dirt in liner and/or contact tip
2)
The frition brake in the hub
is too tightened
3)
Faulty welding torch
1)
Contact tip defect
2)
Burns in contact tip
3)
Dirt in feed roll groove
4)
Feed roll's groove worn
1)
Bad concat between earth clamp
and workpiece
2)
Short-circuit between contact tip
and gas shroud
1)
Failre of gas shield owing to
spatters in gas shro
2)
Wrong welding torch distance
and/or inclination from workpiece
3)
Too small gas flux
4)
Humid workpieces
5)
Heavily rusted workpieces
1)
Welding machine overheated due
to an excessive use in stated duty
cycle
I
maximum

FAULT FINDING

REASON
... (A)
Effective current supplied
1 eff
X
Duty cycle
The
IP21
class
The
H
class.
Welding machine suitable for use
in environments with heightened
risk of electric shock.
Symbols
regulations
REMEDY
Blow with compressed air, replace contact
tip
Loosen
Check sheating of torchès
wire guide
Replace
Replace
Clean
Replace
Tighten earth clamp and check connections
Clean, replace tip and/or shroud as
necessary
Clean gas shroud from spatters
The length of stick out wire from tip must
be 5 – 10mm. Inclination not less than 60
degrees in relation to woekpiece
Increase flux of welding gas
Dry with heat producer
Clean workpieces from rust
Don't switch off the machine, let it cool
down for about 20/30 minutes
welding unit's protection
transformer's
insulation
referring
to
safety

Werbung