1
2
3
1- Position the motor on the DOWN end limit by using the keys DOWN or UP.
2- To memorize the DOWN end limit position, press simultaneoulsy the keys STOP and UP. The motor will run automatically in the UP direction.
3- When the motor arrives on the UP End limit, press the key STOP.
4- If necessary adjust the position with the keys UP or DOWN.
5- To memorize the UP end limit position, press simultaneoulsy the keys STOP and DOWN. The motor will run automatically
in the DOWN direction.
6- Press 2 seconds the STOP key to validate the setting. The motor will stop, and will run for 1/2 second in one direction,
then in the other direction. Go to §5.
- After these operations, you can program the transmitter used before as a 1st control point. To
do so, see chapter §5.
- If you do not want to keep this transmitter and program it, cut the power supply. When you
will program another transmitter with this motor (eg.: after the shutter installation) refer
directly to chapter §4.1. In this case, when you switch on the power supply, the motor must
rotate for 1/2 second in one direction, the in the other. That indicate the end limits are set but
the controls are not programmed. Then go to stage §5 for programming.
Programming the first individual point of control with the Hz receiver
5
This operation can only be performed from the transmitter that was used for operation 4.1.
- Press the transmitter "PROG" Key for approximately
one second. The motor will run for 1/2 second in
one direction and then in the other. Your
transmitter is now programmed to control the
EHz motor in stable mode
Recording and controling intermediate position
6
Recording :
- Position the motor on the
wanted position.
- Press 5 seconds on the "stop"
key. The motor will run for
1/2 second in one direction
and then in the other.
Programming a new (individual, group or main) control point:
7
7.1 : Open the memory of the receiver from the
control transmitter:
- Press the "PROG" key of the transmitter for about 3
seconds. The motor will run for a half a second in
one direction, then in the other.
7.2 : Validate the operation from the new
transmitter you want to programm:
- Press the "PROG" key of the transmitter for about 1
second. The motor will run for a half a second in
one direction, then in the other.
- For group controls, repeat operations 7.1 and 7.2 for each receiver in the group.
- For main controls, repeat operations 7.1 and 7.2 for each receiver in the installation.
- To delete an transmitter from the memory of a receiver, perform operations 7.1 with a
programmed transmitter, then perform the operation 7.2 with the transmitter to be
deleted.
4
5
PROG
Controling :
- Press on the "stop" key for
0,5s. the motor goes to the
intermediate position.
5s
PROG
PROG
Re-adjustement of end limits
8
6
8.1 : Re-adjustement of UP end limits (assemblies B and D only)
1
2s
1- Position the motor on the UP end limit previously set in §4.3 with the UP key.
2- Press simultaneously for 5 seconds the UP and DOWN keys, The motor will run for a half a second in one
direction and then in the other direction.
3- Adjust the new position with the UP and DOWN keys.
4- Validate the new position by pressing 2 seconds the STOP key. The motor will run for a half a second in one
direction and then in the other direction. The new end limits setting is memorized.
8.2 : Re-adjustement of DOWN end limits (assemblies C and D only)
1
1- Position the motor on the DOWN end limit previously set in §4.3 with the DOWN key.
2- Press simultaneously for 5 secondes the UP and DOWN keys, The motor will run for a half a second in one
direction and then in the other direction.
3- Adjust the new position with the UP and DOWN keys.
≤1s >>
4- Validate the new position by pressing 2 seconds the STOP key. The motor will run for a half a second in one
direction and then in the other direction. The new end limits setting is memorized.
- In case A, re-adjustment is automatic.
Cancelling programming
9
9.1
- Switch off the power supply to the motor for 2 seconds.
- Switch on the power supply to the motor for 7 seconds.
- Switch off the power supply to the motor for 2 seconds.
- Switch the power to the motor back on. The
motor will run for 5 seconds in random direction
0,5s
and is now in the "cancelling" mode.
If you switch off the power to several receivers, they will all be in cancelling mode. That is why,
you must "eject" out of this mode all the receivers that are not to be deprogrammed by sending
a command from their individual control transmitter (UP or Down).
≥3s >>
9.2- Then, validate the cancelling of the affected motor from the individual control or from a new
transmitter
- Press the "PROG" key of the transmitter more than
7 seconds. Maintain the pressure until the motor
≤1s
will first run for a half a second in one direction and
>>
then the other, and a few second later, it will run
again in both direction.
The EHz motor is now as it was originally configured, and no transmitter and no settings is saved in
its memory and is ready for a new programming.
Hereby, SIMU, declares that this equipment "T5EHz" is in compliance with the essential requirements and
other relevant provision of Directive 1999/5/EC. A declaration of Conformity is available at the web address:
www.simu.fr, heading "Normes". Usable in UE,
3 / 4
2
3
5s
2
3
5s
OFF
ON
2s
7s
≥7s