Selection of functions
«1 OFF» "Operator present", gate operates only when the pushbutton is held down (the radio remote control system is deactivated)
disabled; (1 ON - enabled)
«2 ON» "Automatic closing" enabled; (2 OFF - disabled)
Adjustment Trimmer
E
Trimmer T.L. = Adjusts operating time from a minimum of 5 seconds to a maximum of 50 seconds.
Trimmer TR2M = Adjusts closing delay of 2nd motor (M2) from a minimum of 1 second to a maximum of 10 seconds.
Trimmer T.C.A. = Adjusts automatic closing time from a minimum of 3 seconds to a maximum of 130 seconds.
Motor torque limiter
To vary the motor torque,
move the indi cated faston
to one of the four positions:
1=min, 4=max