AhSc: Clear high starter battery voltage alarm. When the starter
battery voltage falls below this value, the alarm is turned off. This
value needs to be less than or equal to AhS.
RlS: Relay low starter battery voltage. When the starter battery
voltage falls below this value for more than 10 seconds the relay
will be activated.
RlSc: Clear relay low starter battery voltage. When the starter battery
voltage rises above this value, the relay will be de-activated. This
value needs to be greater than or equal to RlS.
RhS: Relay high starter battery voltage. When the starter battery
voltage rises above this value for more than 10 seconds the relay
will be activated.
RhSc: Clear relay high starter battery voltage. When the starter
battery voltage falls below this value, the relay will be de-activated.
This value needs to be less than or equal to RhS.
D VS: Starter battery voltage display. Determines if the starter battery
voltage is available in the monitoring menu.